Introduction of IC6600 Ion Chromatography Instrument
The IC6600 multi-functional ion chromatograph adopts a brand-new modular design, offering flexible configuration and powerful functionality. While meeting customers' routine detection needs, it can be upgraded with features such as post-column derivatization, online enrichment, and online baseline elimination. Its water-only mode eluent generator can produce the required eluent online. The five-zone temperature control mode for separation, detection, and derivatization modules provides higher temperature stability.
Technical Parameters of IC600 Ion Chromatography Instrument
| Product Name | Multifunctional Ion Chromatography |
| Model | IC6600 |
| Working power | 220V, 50Hz |
| Ambient temperature | 10-40°C |
| Relative humidity | 20-85% |
| Qualitative repeatability | ≤0.1% |
| Quantitative repeatability | ≤0.5% |
| Pump flow rate range | 0.001~12.000mL/min |
| Pressure resistance of pump head | 0-40MPa |
| Flow setting error | <0.1% |
| Flow stability | <0.1% |
| Pressure display accuracy | 0.001MPa |
| Pressure plusation | <0.25% |
| Conductivity detector | |
| Baseline noise | ≤0.03%FS |
| Baseline drift | ≤0.1%FS |
| Mini detectable concentration (Cl): | ≤0.0001μg/mL |
| Mini detectable concentration (Li): | ≤0.00005μg/mL |
| Mini detectable concentration (NO3): | ≤0.001μg/mL |
| Mini detectable concentration (Na+): | ≤0.001μg/mL |
| Mini detectable concentration (Ca2+): | ≤0.005μg/mL |
| Conductivity cell volume | ≤0.4μL |
| Conductivity detection range | 0-45000μS/cm |
| Detector resolution | 0.00238nS/cm |
| Conductivity cell temperature setting error | ±0.01°C |
| Conductivity cell temperature display resolution | 0.001°C |
| Conductivity cell temperature control range | Detector temperature zone temperature +5°C-65°C |
| Conductivity cell temperature control stability | 0.05°C |
| Conductivity cell temperature setting value error | 0.1°C/h |
| Ampere detector | |
| Type | Thin-layer structure, automatic range |
| Driving voltage range | -2.0V-2.0V |
| Drive voltage resolution | 0.001V |
| Output signal range |
Integral mode: 50pc-200uC DC mode: 1pA-74μA |
| Noise |
Integration mode<30pC DC mode<5pA, DC mode static noise<1pA |
| Cell material | Titanium |
| Pool volume | <0.2μL |
| Maximum pool pressure | 0.7MPa |
| Minimum detectable concerntration | I-0.001μg/mL |
| Minimum detectable concerntration fructose | 0.01μg/mL |
| UV Detector | |
| Wavelength indication error | 0.1nm |
| Wavelength repeatability | 0.1nm |
| Mini detectable concentration | BrO3-0.0005μg/mL |
| Mini detectable concentration | CrO42-0.001μg/mL |
| Qualitative repeatability | ≤0.05% |
| Quantitative repeatability | ≤0.3% |
| Suppressor | |
| Dead volume | 50μL |
| Inhibition capacity | 170ueq/min |
| Pressure resistance | 3MPa |
| Column oven | |
| Temperature range | Room temperature +5°C~70°C |
| Temperature control stability | 0.1°C/h |
| Error of temperature setting value | 0.05°C |
| Autosampler | |
| Number of samples | ≥120 (1.5ml sample bottle) |
| Temperature | 4~30°C |
| Linear | >0.999 |
| Cross-contamination | <0.01% |