Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
CE
Model Number:
IC6600
Introduction of IC6600 Ion Chromatography Instrument
The Ion Chromatography Instrument is an advanced analytical device designed to deliver exceptional performance and reliability in ion detection and quantification. Engineered with precision, this instrument offers outstanding qualitative repeatability, ensuring consistent and accurate results with a variability of less than or equal to 0.1%. This high level of repeatability makes the Ion Chromatography Instrument an ideal choice for laboratories requiring dependable data for research, quality control, and routine analysis.
Technical Parameters of IC6600 Ion Chromatography Instrument
| Product Name | Multifunctional Ion Chromatography |
| Model | IC6600 |
| Working power | 220V, 50Hz |
| Ambient temperature | 10-40°C |
| Relative humidity | 20-85% |
| Qualitative repeatability | ≤0.1% |
| Quantitative repeatability | ≤0.5% |
| Pump flow rate range | 0.001~12.000mL/min |
| Pressure resistance of pump head | 0-40MPa |
| Flow setting error | <0.1% |
| Flow stability | <0.1% |
| Pressure display accuracy | 0.001MPa |
| Pressure plusation | <0.25% |
| Conductivity detector | |
| Baseline noise | ≤0.03%FS |
| Baseline drift | ≤0.1%FS |
| Mini detectable concentration (Cl): | ≤0.0001μg/mL |
| Mini detectable concentration (Li): | ≤0.00005μg/mL |
| Mini detectable concentration (NO3): | ≤0.001μg/mL |
| Mini detectable concentration (Na+): | ≤0.001μg/mL |
| Mini detectable concentration (Ca2+): | ≤0.005μg/mL |
| Conductivity cell volume | ≤0.4μL |
| Conductivity detection range | 0-45000μS/cm |
| Detector resolution | 0.00238nS/cm |
| Conductivity cell temperature setting error | ±0.01°C |
| Conductivity cell temperature display resolution | 0.001°C |
| Conductivity cell temperature control range | Detector temperature zone temperature +5°C-65°C |
| Conductivity cell temperature control stability | 0.05°C |
| Conductivity cell temperature setting value error | 0.1°C/h |
| Ampere detector | |
| Type | Thin-layer structure, automatic range |
| Driving voltage range | -2.0V-2.0V |
| Drive voltage resolution | 0.001V |
| Output signal range |
Integral mode: 50pc-200uC DC mode: 1pA-74μA |
| Noise |
Integration mode<30pC DC mode<5pA, DC mode static noise<1pA |
| Cell material | Titanium |
| Pool volume | <0.2μL |
| Maximum pool pressure | 0.7MPa |
| Minimum detectable concerntration | I-0.001μg/mL |
| Minimum detectable concerntration fructose | 0.01μg/mL |
| UV Detector | |
| Wavelength indication error | 0.1nm |
| Wavelength repeatability | 0.1nm |
| Mini detectable concentration | BrO3-0.0005μg/mL |
| Mini detectable concentration | CrO42-0.001μg/mL |
| Qualitative repeatability | ≤0.05% |
| Quantitative repeatability | ≤0.3% |
| Suppressor | |
| Dead volume | 50μL |
| Inhibition capacity | 170ueq/min |
| Pressure resistance | 3MPa |
| Column oven | |
| Temperature range | Room temperature +5°C~70°C |
| Temperature control stability | 0.1°C/h |
| Error of temperature setting value | 0.05°C |
| Autosampler | |
| Number of samples | ≥120 (1.5ml sample bottle) |
| Temperature | 4~30°C |
| Linear | >0.999 |
| Cross-contamination | <0.01% |
Send your inquiry directly to us