logo

IC6200 Ion Chromatography Instrument Flow Rate Range 0.001-12 mL/min

Basic Properties
Place of Origin: Anhui, China
Brand Name: Wayeal
Certification: ISO, CE
Model Number: IC2300
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiate
Payment Terms: T/T
Supply Ability: 30 Units/Month
Specifications
Working Temperature: 10~40°C Qualitative Repeatability: ≤ 0.05%
Quantitative Repeatability: ≤ 0.2% Flow Rate Range: (0.001–12.000) ML/min
Pump Pressure: (0–42) MPa Flow Rate Set Error: ≤ ±0.1%
Injection Positions: 48 Or 120 Positions Power Supply: 220V, 50~60Hz
High Light:

KOH Ion Chromatography Instrument

,

100.0mM Ion Chromatography Instrument

Product Description

System Introduction of IC6200 Ion Chromatography Machine

The Wayeal IC6200 Integrated Ion Chromatography System is a next-generation intelligent platform designed for high-precision anion and cation analysis. Featuring a full PEEK non-metallic flow path, electrolytic self-regenerating membrane suppressor, and integrated column oven with ±0.01°C temperature stability, the IC6200 delivers exceptional reproducibility and long-term reliability. Its 10-inch smart touchscreen, ambient lighting, and one-button intelligent maintenance simplify operation while enhancing laboratory productivity.

System Parameters Of IC6200 Ion Chromatography Instrument

System Parameter

 

Qualititative Repeatability

≤0.05%

Quantitative Repeatability

≤0.2%

Pump System

 

Flow Rate (Full PEEK Pump)

(0.001–12.000) mL/min

Pump Head Pressure Resistance

(0–42) MPa

Flow Rate Set Error

≤ ±0.1%

Flow Rate Stability

≤ ±0.1%

Pressure Display Resolution

0.01 MPa

Suppressor

 

Suppressor Type

Electrolytic self-regenerating membrane suppressor

Constant Current Range

0–500 mA, adjustable in increments of 1 mA

Column Oven

 

Temperature Range

Ambient +5°C to 85°C

Temperature Stability

±0.01°C

Compatibility

Compatible with 250 mm and 150 mm length columns

AS2800 Series Autosampler

 

Quantitative Repeatability

< 0.5% RSD (full-loop injection)

Sample Positions

48 positions / 11 positions

Wash Ports

2 ports (fine wash and coarse wash)

Operating Temperature

10–40°C

Vial Types

5mL/ 100mL

Injection Volume

10 µL – 4000 µL (depending on sample loop size)

Single Injection Cycle Time

Approx. 20s (depending on wash time and injection volume)

Injection Mode

Full-loop injection

AS3110 Series Autosampler

 

Sample Capacity

64/120 positions

Cooling Temperature Range

4–30°C

Repeatability

< 0.3% RSD (full-loop injection, injection volume > 5 µL)

Syringe Specifications

Standard: 500 µL; Optional: 250 µL, 1000 µL, 2500 µL

Sample Loop Specifications

Standard: 100 µL; Optional: 25 µL, 50 µL, 200 µL

Carryover (Cross Contamination)

< 0.01%