logo

42MPa PEEK Pump High-Pressure Ion Chromatograph Instrument Lab IC System

Basic Properties
Place of Origin: Anhui, China
Brand Name: Wayeal
Certification: ISO, CE
Model Number: IC6200
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiate
Payment Terms: T/T
Supply Ability: 30 Units/Month
Specifications
Qualitative Repeatability: ≤ 0.05% Column Capacity: 2pcs, 250mm And 150mm
Injection Positions: 48 Or 120 Positions Working Temperature: 10~40°C
Wash Ports: 2 Ports,fine Wash And Coarse Wash Temperature Range: Ambient +5°C To 85°C
Quantitative Repeatability: ≤ 0.2% Pump Pressure: (0–42) MPa
High Light:

Quantitative Repeatability Ion Chromatography Instrument

,

30min Ion Chromatography Instrument

,

Ion Chromatography Instrument For Analysis

Product Description

Introduction of IC6200 Ion Chromatpgraphy Instrument

The Ion Chromatography Instrument is a powerful and reliable tool for anyone who needs accurate and consistent ion analysis. So whether you are a seasoned researcher or a new laboratory technician, you can depend on this instrument to deliver the results you need.

Techncial Parameters of IC6200 Ion Chromatography Instrument

System Parameter

 

Qualititative Repeatability

≤0.05%

Quantitative Repeatability

≤0.2%

Pump System

 

Flow Rate (Full PEEK Pump)

(0.001–12.000) mL/min

Pump Head Pressure Resistance

(0–42) MPa

Flow Rate Set Error

≤ ±0.1%

Flow Rate Stability

≤ ±0.1%

Pressure Display Resolution

0.01 MPa

Suppressor

 

Suppressor Type

Electrolytic self-regenerating membrane suppressor

Constant Current Range

0–500 mA, adjustable in increments of 1 mA

Column Oven

 

Temperature Range

Ambient +5°C to 85°C

Temperature Stability

±0.01°C

Compatibility

Compatible with 250 mm and 150 mm length columns

AS2800 Series Autosampler

 

Quantitative Repeatability

< 0.5% RSD (full-loop injection)

Sample Positions

48 positions / 11 positions

Wash Ports

2 ports (fine wash and coarse wash)

Operating Temperature

10–40°C

Vial Types

5mL/ 100mL

Injection Volume

10 µL – 4000 µL (depending on sample loop size)

Single Injection Cycle Time

Approx. 20s (depending on wash time and injection volume)

Injection Mode

Full-loop injection

AS3110 Series Autosampler

 

Sample Capacity

64/120 positions

Cooling Temperature Range

4–30°C

Repeatability

< 0.3% RSD (full-loop injection, injection volume > 5 µL)

Syringe Specifications

Standard: 500 µL; Optional: 250 µL, 1000 µL, 2500 µL

Sample Loop Specifications

Standard: 100 µL; Optional: 25 µL, 50 µL, 200 µL

Carryover (Cross Contamination)

< 0.01%