Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
CE
Model Number:
IC6300
Ion Chromatography Instrument Introduction:
Ion Chromatography Instrument
Ion chromatography instrument, a form of liquid chromatograph, measures concentrations of ionic species by separating them based on their interaction with a resin. Ionic species separate differently depending on species type and size. Sample solutions pass through a pressurized chromatographic column where ions are absorbed by column constituents. As an ion extraction liquid, known as eluent, runs through the column, the absorbed ions begin separating from the column. The retention time of different species determines the ionic concentrations in the sample.Ion chromatography instrument is used for water chemistry analysis. Ion chromatographs are able to measure concentrations of major anions, such as fluoride, chloride, nitrate, nitrite, and sulfate, as well as major cations such as lithium, sodium, ammonium, potassium, calcium, and magnesium in the parts-per-billion (ppb) range. Concentrations of organic acids can also be measured through ion chromatography instrument.
IC6300 Fully PEEK Material Ion Chromatography Instrument for Anions and Cations Analysis |
|
---|---|
Product Name |
Ion Chromatography Instrument |
Working Conditions |
|
Working Power |
220V, 50Hz |
System Parameters |
|
Qualitative Repeatability |
≤1% |
Quantitative Repeatability |
≤1% |
Pump System |
|
Flow Rate |
0.001~15.000mL/min |
Pressure Range |
0~42MPa |
Flow Rate Setting Error |
<0.2% |
Flow Rate Stability |
<0.2% |
Eluent |
|
Flow Rate Range |
0.001~3.000ml/min |
Eluent Concentration Range |
KOH/MSA 0.1~100.0mM |
Accuracy of Concentration |
0.1mM |
Max Working Pressure |
21MPa (3000psi) |
Autosampler (AS2800 series) |
|
Quantitative Repeatability |
Full loop injection <0.5%RSD |
Linearity |
>0.9995 |
Injection Positions |
48 Positions |
Working Temperature |
10~40°C |
Sample Bottle |
5mL/100mL |
Injection Volume |
10uL~400uL |
Autosampler (AS3110 Series) |
|
Injection Positions |
120/64/92 positions for optional |
Cooling Temperature |
4~30°C |
Injector |
Standard 500ul, options 250ul, 100ul, 2500ul |
Column Oven |
|
Temperature Range |
Room temperature, +5℃~70℃ |
Temperature Control Stability |
≤0.1°C |
Temperature Setting Error |
0.05°C |
Column Capacity |
250mm and 150mm |
Suppressor |
|
Dead Volume |
50uL |
Suppression Capacity |
170ueq/min |
Pressure Resistance |
3MPa |
Conductivity Detector |
|
Baseline Noise |
≤0.0005μS/cm |
Baseline Drift |
≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) |
≤0.0005ug/mL |
Min Detection Concentration (Li) |
≤0.0002ug/mL |
Cell Volume |
≤0.4μL |
Detector Resolution |
0.00238nS/cm |
Temperature Setting Error |
±0.01°C |
Ampere Detector |
|
Drive Voltage Range |
-2.048V---2.048V |
Drive Voltage Resolution |
0.001V |
Single Input Range |
Integral mode, 50pc---200uC |
DC mode |
1pA---74uA |
Cell Volume |
<0.2uL |
Min Detection Concentration |
I: 0.001μg/mL |
Performance of Ion Chromatography Instrument
1. The highest pressure resistant all-PEEK ion chromatography pump with a pressure resistance of up to 42Mpa;
2. Flexible switching of isocratic pump and quaternary pump to meet the needs of various experiments and tests.
3. Reagent-free ion chromatography, which utilizes deionized water electrolysis to produce a precise concentration of eluent, dramatically improves the reproducibility of experimental results.
Wayeal IC6300 is an advanced ion chromatography instrument designed and produced by Wayeal, a leading manufacturer in the field of analytical instruments. It is widely used in various industries and research institutions for the analysis and separation of ions in liquid samples.
Some typical applications of ion chromatography instrument include:
1. Drinking water analysis for pollution and other constituents
2. Determination of water chemistries in aquatic ecosystems
3. Determination of sugar and salt content in foods
4. Isolation of select proteins
Send your inquiry directly to us