Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
CE
Model Number:
IC6300
Introduction of Ion Chromatogrphy Instrument:
Ion Chromatography Instrument
The Ion Chromatography Instrument is an advanced analytical tool designed for the separation and measurement of ions in a liquid sample. It is an essential instrument used in various industries, including environmental testing, pharmaceuticals, food and beverage, and research laboratories. It is equipped with advanced technology and features to meet the growing demands of the industry. With a compact design and user-friendly interface, this instrument is easy to use and provides quick and accurate results.
Technical Parameters of Ion Chromatography Instrument:
IC6300 Good Separation Ion Chromatography Instrument for Ions Analysis in Water |
|
---|---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21MPa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10uL~400uL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500ul, options 250ul, 100ul, 2500ul |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50uL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3MPa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005ug/mL |
Min Detection Concentration (Li) | ≤0.0002ug/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2uL |
Min Detection Concentration | I: 0.001μg/mL |
1. Self-created eluent liquid purification system, effectively removes trace impurity ions and provides ultra-pure eluent liquid system.
2. Conductivity, amperometric, ultraviolet, fluorescence and other types of detectors to choose flexibly, expanding the scope of ion chromatography applications.
3. The amperage detector supports a variety of detection modes such as DC amperage, pulsed amperage, and integral amperage.
Ion chromatography instrument is used for water chemistry analysis. Ion chromatographs are able to measure concentrations of major anions, such as fluoride, chloride, nitrate, nitrite, and sulfate, as well as major cations such as lithium, sodium, ammonium, potassium, calcium, and magnesium in the parts-per-billion (ppb) range.
Send your inquiry directly to us