Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
IC6600
Double System Ion Chromatography Instrument with Conductivity Amperometric Detectors
Product Introduction
Ion chromatography (or ion-exchange chromatography) is a chromatography process that separates ions and polar molecules based on their affinity to the ion exchanger. It works on almost any kind of charged molecule—including large proteins, small nucleotides, and amino acids. The two types of ion chromatography are anion-exchange and cation-exchange. It is often used in protein purification, water analysis, and quality control.
Product Features
1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time
5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.
Product Parameter
Infusion system
Eluent Generator
Double System Ion Chromatography Instrument with Conductivity Amperometric Detectors | |
System Parameters | |
Qualitative repeatability | ≤1% |
Quantitative repeatability | ≤1% |
Pump System | |
Pump flow rate | (0.001~12.000)mL/min |
Pressure Resistance | (0.001~12.000)mL/min |
Flow rate setting error | <0.1% |
Flow rate stability | <0.1% |
Pressure display accuracy | 0.01Mpa |
Pressure pulsation | <0.25% |
Amperage Detector | |
Type | Thin layer structure, automatic range |
ve voltage range | -2.048V---2.048V |
Drive voltage resolution | 0.001V |
Output signal range | 50pc---200uC |
DC mode | 1pA---74uA |
Noise | Integral mode <30pC |
Cell volume | <0.2uL |
Min detection concentration | I-——0.001μg/mL |
Min detection concentration | Fructose - 0.01μg/mL |
Min detection concentration | CN-——0.0005μg/mL |
Suppressor | |
Constant current range | 0-500mA |
Dead volume | 50uL |
Suppressor volume | 170ueq/min |
Pressure resistance | 3MPa |
Column Oven | |
Temperature range | Room +5°C~70°C |
Temperature control stability | ≤0.1℃ |
Temperature seeting error | 0.05℃ |
Autosampler | |
Quantitative repeatability | Full loop injection <0.5%RSD |
Linear | >0.9995 |
Injection positions | 48 vials |
Washing bit | 2 bits (fine and coarse) |
Working temperature | 10-40℃ |
Injection volume | 10uL---4000uL |
Industry Application
Environment, food, medicine, agriculture, grain and oil, and chemical industry