Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Ion Chromatograph With Conductivity Detector | Application | Inorganic Anion Detection |
---|---|---|---|
Power Supply | 220V, 50~60Hz | Pressure Pulsation | <0.5% |
Baseline Noise | ≤0.05%FS | Baseline Drift | ≤0.4%FS |
High Light | In Line Eluent Ion Chromatography Instruments,220V 50Hz Ion Chromatography Instrument,220V 60Hz Ion Chromatography Instrument |
In-line Eluent Generation Ion Chromatograph Instruments with Conductivity Detector
Product Introduction
IC analysis uses a High Performance Liquid Chromatography (HPLC) system equipped with a conductivity detector to separate anions or cations. The ions in a sample are moved through the system in solution and then the various ions are separated in a column with an ion-exchange resin. The resin’s surface layer has limited ion-exchange sites that attract either anions or cations. A conductivity detector at the end of the column measures the quantity of exiting ions, and from this data a chromatogram is produced.
Product Features
1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.
5. Powerful and convenient chromatpgraphy workstation
6. High precision temperatur-controlled conductivity detector.
Product Parameter
In-line Eluent Generation Ion Chromatograph Instruments with Conductivity Detector | |
Qualitative Repeatability | ≤0.05% |
Quantitative Repeatability | ≤0.3% |
Pump System | |
Flow Rate | (0.001~12.000) mL/min |
Pump Head Pressure Resistance | (0 ~ 40) MPa |
Flow Rate Setting Inaccuracy | <0.05% |
Flow Stability | <0.05% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.05%FS |
Baseline Drift | ≤0.4%FS |
Minimum Detectable Concentration (Cl) | ≤ 0.0001ug/mL |
Minimum Detection Concentration (Li) | ≤ 0.0005ug/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000 μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5ml standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5uL) |
Syringe Size | Standard: 500ul; optional; 250ul, 1000ul, 2500ul |
Loop Size |
Standard: 100ul; optional: 20ul, 50ul, 200ul |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator |
|
Flow Rate Range | 0.001 to 3.000ml/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21MPa (3000psi) |
Gradient Accuracy | 1.5% |
Industry Application
Detection of inorganic anions, iodides, disinfection by-products, adsorbable organohalogens, glyphosate, soluble cations and hexavalent chromium in environmental water quality.