Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
High Performance FID Gas Chromatograph Mass Spectrometer GC MS Instrumentation
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xName | Wayeal High Performance Gas Chromatography Instrument Machine Price | Detection Limit | 2×10 -12g/s |
---|---|---|---|
Detector | FID Detector | Column Quantities | 2 Columns |
Qualitative Repeatability | ≤0.05% | Position | 16 |
High Light | gas chromatograph mass spectrometer,FID gas chromatograph mass spectrometer,FID gc ms instrumentation |
Wayeal High Performance Gas Chromatography Instrument Machine Price
Product Introduction
GC6000 gas chromatography instrument is composed of an injector, detector, column, column temperature chamber, separation system and data processing system.
Product Parameter
Gas Chromatography Instrument | |
Color | White+Blue |
Sample Positions | 16 |
Stationary Phase | Solid Adsorbent |
Mobile Phase | Liquid |
Detector | FID Detector |
Sampler | Six-way valve |
Circuit System | 3 |
Qualitative Repeatability | ≤0.05% |
Detection Limit | 14×10 -15g/ml |
Linear Range | ≥10 4 |
Baseline Noise | ≤0.05mV |
Drift | ≤0.05mV |
Product Performance
1.1 Very low noise, FID noise is better than the international leading level;
1.2 High sensitivity detector, low baseline drift;
1.3 Good reproducibility of peak area and retention time;
1.4 High temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.
2. Flexibility and scalability
2.1 Optional multiple detectors (FID, FPD, ECD);
2.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;
2.3 Flexible syringe injection system, optional autosampler or six-port valve injection;
Product Application
Environmental Protection: Trace Toxicants in Air and Water Contaminated Areas Analysis, monitoring and research
Biochemistry: clinical applications, pathology and toxicology studies.