Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
IC6200
IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations Analysis
Introduction of Ion Chromatography Instrument
Ion chromatography instrument is a kind of high performance liquid chromatography, so it is also called high performance ion chromatography (HPIC) or modern ion chromatography. It is different from traditional ion exchange column chromatography mainly because that resin has high cross-linking degree and low exchange capacity, the sample volume is very small, and normally, a plunger pump is used to pump eluent for on-line automatic continuous conductivity detection of leachate.
Features of Ion Chromatography Instrument
1. Intergrated design, LCD full touch GUI controller
2. High degree of automation, one key flushing, one key maintenance
3. Higher integration: support optional parts upgrade to 2D system and multi-detector coupling.
4. All-plastic non-metallic flow path.
5. Highly precise temperature control for the whole system.
6. Precision PEEK material ion chromatography pump.
7. Electrolytic self-regenerating membrane suppressor.
8. High-precision temperature-controlled conductivity detector.
9. Powerful and easy-to-use chromatography workstation.
Parameters of Ion Chromatography Instrument
IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations Analysis | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | (0.001~10.000)mL/min |
Pump Head Pressure Resistance | (0 ~ 35) Mpa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤0.0002μg/mL |
Minimum Detection Concentration (Li) | ≤0.0001μg/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5mL standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5μL) |
Syringe Size | Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size | Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow Rate Range | 0.001 to 3.000mL/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21Mpa (3000psi) |
Gradient Accuracy | 1.5% |
Industry Application
Environment, food, medicine, agriculture, grain and oil, and chemical industry