IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven

Double System Ion Chromatography Instrument

40Mpa Ion Chromatography System

Ion Chromatography Instrument 40Mpa

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO, CE

Model Number:

IC6620

Contact Us
Request A Quote
Product Details
Product Name:
Ion Chromatography Instrument
Detector:
Conductivity Detector
Baseline Noise:
≤0.0004μS/cm
Baseline Drift:
≤0.004μS·cm-1/30min
Conductivity Cell Pressure Resistance:
15MPa
Cell Volumn:
≤0.4μL
High Light:

Double System Ion Chromatography Instrument

,

40Mpa Ion Chromatography System

,

Ion Chromatography Instrument 40Mpa

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
One piece per wooden case
Delivery Time
20 days
Payment Terms
L/C, T/T
Supply Ability
30 Pieces Per Month
RELATED PRODUCTS
Contact Us
Product Description

IC6620 40Mpa Double System Ion Chromatography with Suppressor and Column Oven

 

Product Introduction

 

Ion Chromatography (IC) is a useful tool for determining the presence and concentration of ions in samples and is utilized in numerous settings including environmental analyses such as the determination of anions (PO43-, Cl-, NO3-, etc) in surface waters. Current IC methods are often used to quantify concentrations in the low ppm level, depending upon the specific instrumentation used.

 

Product Features

 

1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time

5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.

 

Product Parameter

IC6620 40Mpa Double System Ion Chromatography with Suppressor and Column Oven
Working power 220V, 50Hz
Ambient temperature 10-40℃
Relative humidity 20%-85%
Pump System  
Flow Rate (0.001~12.000) mL/min
Pressure resistance (0~40) MPa
Flow rate setting error <0.18%
Flow rate stability <0.18%
Pressure display accuracy 0.01Mpa
Pressure pulsation <0.25%
Conductivity Detector  
Baseline noise ≤0.0004μS/cm
Baseline drift ≤0.004μS-cm-1/30min
Minimum detectable concentration (Cl) ≤0.0004ug/mL
Minimum detection concentration (Li) ≤0.0001ug/mL
Minimum detectable concentration (NO3-) ≤ 0.001μg/mL
Minimum detectable concentration (Na+) ≤ 0.001μg/mL
Minimum detected concentration (Ca2+) ≤ 0.005μg/mL
Conductivity cell volume ≤ 0.4 μL
Conductivity detection range 0-45000μS/cm
Detector resolution 0.00238nS/cm
Conductivity cell temperature setting error ±0.01°C
Conductivity cell temperature control stability 0.05 ℃
Conductivity cell temperature setting error 0.1 ℃ / h
Conductivity cell pressure resistance 15 MPa
Column Oven  
Temperature range Room temperature +5℃~70℃
Temperature control stability ≤0.1℃
Temperature setting error 0.05℃
Autosampler  
Quantitative repeatability <0.5% RSD for full-loop sampling
Linearity >0.9995
Number of sample vials AS2800D, 48 Vials autosampler
Operating temperature 10-40°C
Sampling volume 10uL --- 4000uL
Single sampling cycle About 20s
Sampling method Full-loop sampling
Eluent Generator  
Flow rate range 0.001 to 3.000 ml/min
Eluent concentration range KOH, MSA-0.1~100.0mM
Concentration accuracy 0.1mM
Electrolyte original concentration 25% KOH/MSA
Electrolyte volume 1000mL
Maximum working pressure 21MPa (3000psi)
Gradient accuracy 1.5%

 

Industry Application

 

It can be used for the detection and analysis of anions (e.g. F- , Cl- , Br- , BrO3- , NO3- , NO2- , SO42- , PO43- , disinfection by-products, etc.) and cations (e.g. Li+ , Na+ , NH4+ , K+ , Mg2+ , Ca2+ , etc.).

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 0

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 1

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 2

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 3

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 4

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 5

IC6620 Double System Ion Chromatography 40Mpa With Suppressor And Column Oven 6

 

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality Helium Leak Detector Supplier. Copyright © 2022-2024 Anhui Wanyi Science and Technology Co., Ltd. . All Rights Reserved.