IC6610 Integrated Dual System Multifunctional Ion Chromatography Instrument
Product Introduction
Ion Chromatography is a well established ion exchange chromatography technique for the analysis of anions and cations. In contrast to general HLPC systems, often suitable for a wide range of applications, ion chromatographs are chromatography systems specifically adapted for the analysis of anions and cations. Metal-free flow paths, conductivity detection and ion suppression of eluent ions are a few of the specific necessities to enable reliable chromatographic analysis of anions, cations, organic acids, transition metals and amines.
Product Features
1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time
5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.
Product Parameter
IC6610 Integrated Dual System Multifuncational Ion Chromatography Instrument | |
System Parameter | |
Qualitative repeatability | ≤0.1% |
Quantitative repeatability | ≤0.5% |
Pump System | |
Flow Rate | 0.001~12.000 mL/min |
Pressure Resistance | 0~40 MPa |
Flow Rate Setting Error | <0.1% |
Flow Rate Stability | <0.1% |
Pressure Display Accuracy | 0.001Mpa |
Pressure Pulsation | <0.25% |
Conductivity Detector | |
Baseline Noise | ≤0.03%FS |
Baseline Drift | ≤0.1%FS |
Minimum detection concentration (Cl) | ≤0.0001ug/mL |
Minimum detection concentration (Li) | ≤0.00005ug/mL |
Minimum detection concentration (NO3-) | ≤ 0.001μg/mL |
Minimum detection concentration (Na+) | ≤ 0.001μg/mL |
Minimum detectable concentration (Ca2+) | ≤ 0.005μg/mL |
Cell Volume | ≤ 0.4μL |
Detection Range | 0-45000μS/cm |
Detector Resolution | 0.00238nS/cm |
Cell temperature setting error | ± 0.01 ℃ |
Temperature compensation range | 1.5-3.0% |
Temperature control stability | 0.05 ℃ |
Cell pressure resistance | 15MPa |
Suppressor | |
Constant current source range | 0-500mA |
Dead volume | 50uL |
Pressure resistance | 3MPa |
Suppression capacity | 170ueq/min |
Column Oven | |
Temperature range | Room temperature +5℃~70℃ |
Temperature control stability | 0.1℃/h |
Temperature setting error | 0.05℃ |
Autosampler | |
number of sample vials | ≥ 120, 1.5ml sample bottle |
Repeatability | Full-loop injection <0.3% RSD (injection volume >5uL) |
Syringe specifications | standard: 500ul; optional; 250ul, 1000ul, 2500ul |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow rate range | 0.001~3.000ml/min |
Eluent concentration range | KOH, MSA-0.1~100.0mM |
Concentration accuracy | 0.1mM |
Electrolyte original concentration | 25% KOH/MSA |
Maximum working pressure | 21MPa (3000psi) |
Gradient accuracy | 1.5% |
Industry Application
It can be used for the detection and analysis of anions (e.g. F- , Cl- , Br- , BrO3- , NO3- , NO2- , SO42- , PO43- , disinfection by-products, etc.) and cations (e.g. Li+ , Na+ , NH4+ , K+ , Mg2+ , Ca2+ , etc.).