logo
Home > products > Ion Chromatography Instrument >
IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa

IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa

IC6210 Ion Chromatography Instrument

Ion Chromatography Instrument With Conductivity Detector

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO, CE

Model Number:

IC6200

Contact Us
Request A Quote
Product Details
Product Name:
Ion Chromatography Instrument
Detector:
Conductivity Detector, Ampere Detector, UV Detector
Working Power:
220V, 50HZ
Ambient Temperature:
10-40℃
Baseline Noise:
≤0.03%FS (Conductivity Detector)
Baseline Drift:
≤0.1%FS (Conductivity Detector)
Highlight:

IC6210 Ion Chromatography Instrument

,

Ion Chromatography Instrument With Conductivity Detector

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
Wooden Case
Delivery Time
30 days
Payment Terms
L/C, T/T
Supply Ability
30pcs/month
Product Description

IC6210 Integrated Ion Chromatography Instruments with Conductivity Detector

Introduction of Ion Chromatography Instrument

Ion chromatography, a form of liquid chromatography, measures concentrations of ionic species by separating them based on their interaction with a resin. Ionic species separate differently depending on species type and size. Sample solutions pass through a pressurized chromatographic column where ions are absorbed by column constituents. As an ion extraction liquid, known as eluent, runs through the column, the absorbed ions begin separating from the column. The retention time of different species determines the ionic concentrations in the sample.

Features of Ion Chromatography Instrument

1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time

5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.

Parameters of Ion Chromatography Instrument

In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector
System Parameter  
Qualitative Repeatability ≤0.5%
Quantitative Repeatability ≤1%
Pump System  
Flow Rate (0.001~10.000)mL/min
Pump Head Pressure Resistance (0 ~ 35) Mpa
Flow Rate Setting Inaccuracy <0.1%
Flow Stability <0.1%
Pressure Display Accuracy 0.01Mpa
Pressure Pulsation <0.5%
Conductivity Detector  
Baseline Noise ≤0.1%FS
Baseline Drift ≤0.5%FS
Minimum Detectable Concentration (Cl) ≤0.0002μg/mL
Minimum Detection Concentration (Li) ≤0.0001μg/mL
Conductivity Cell Volume ≤ 0.6μL
Conductivity Detection Range 0-15000μS/cm
Detector Resolution 0.00238nS/cm
Conductivity Cell Temperature Setting Error ±0.01°C
Resolution of Conductivity Cell Temperature Display 0.001°C
Suppressor  
Constant Current Source Range 0-500mA in 0.1mA increments
Column Oven  
Temperature Range Room temperature +5°C~85°C
Control Temperature Stability ≤ 0.1°C
Autosampler  
Number of Sample Vials ≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5μL)

Syringe Size Standard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop Size Standard: 100μL; optional: 20μL, 50μL, 200μL
Linearity >0.999
Cross-contamination <0.01%
Eluent Generator  
Flow Rate Range 0.001 to 3.000mL/min
Eluent Concentration Range KOH, MSA-0.1 to 100mM
Concentration Accuracy 0.1mM
Original Concentration of Electrolyte 25% KOH/MSA
Volume of Electrolyte 1000mL
Maximum Working Pressure 21Mpa (3000psi)
Gradient Accuracy 1.5%

Industry Application

It can be used for the detection and analysis of anions (e.g. F- , Cl- , Br- , BrO3- , NO3- , NO2- , SO42- , PO43- , disinfection by-products, etc.) and cations (e.g. Li+ , Na+ , NH4+ , K+ , Mg2+ , Ca2+ , etc.).

IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 0

IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 1

IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 2IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 3IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 4IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 5IC6200 0.001~10.000mL Flow Rate Range Ion Exchange Chromatography Instrument 35Mpa 6

 

 

 