Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
IC6200
Wayeal IC6200 Integrated Ion Chromatography Instrument for Cations or Anions Analysis
Introduction of Ion Chromatography Instrument
Ion chromatography (or ion-exchange chromatography) is a chromatography process that separates ions and polar molecules based on their affinity to the ion exchanger, based on the electrical charge of the protein, which has both positively and negatively charged chemical groups and can be altered by changes in the pH of the buffer, utilizing a gradient of linearly increasing salt concentration.
Features of Ion Chromatography Instrument
1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.
5. One-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning effect
Product Parameter
Wayeal IC6200 Integrated Ion Chromatography Instrument for Cations or Anions Analysis |
|
System Parameter |
|
Qualitative Repeatability |
≤0.5% |
Quantitative Repeatability |
≤1% |
Pump System |
|
Flow Rate |
(0.001~10.000)mL/min |
Pump Head Pressure Resistance |
(0 ~ 35) MPa |
Flow Rate Setting Inaccuracy |
<0.1% |
Flow Stability |
<0.1% |
Pressure Display Accuracy |
0.01Mpa |
Pressure Pulsation |
<0.5% |
Conductivity Detector |
|
Baseline Noise |
≤0.1%FS |
Baseline Drift |
≤0.5%FS |
Minimum Detectable Concentration (Cl) |
≤0.0002μg/mL |
Minimum Detection Concentration (Li) |
≤0.0001μg/mL |
Conductivity Cell Volume |
≤ 0.6μL |
Conductivity Detection Range |
0-15000μS/cm |
Detector Resolution |
0.00238nS/cm |
Conductivity Cell Temperature Setting Error |
±0.01°C |
Resolution of Conductivity Cell Temperature Display |
0.001°C |
Suppressor |
|
Constant Current Source Range |
0-500mA in 0.1mA increments |
Column Oven |
|
Temperature Range |
Room temperature +5°C~85°C |
Control Temperature Stability |
≤ 0.1°C |
Autosampler |
|
Number of Sample Vials |
≥ 120 (1.5mL standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5uL) |
Syringe Size |
Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size |
Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity |
>0.999 |
Cross-contamination |
<0.01% |
Eluent Generator |
|
Flow Rate Range |
0.001 to 3.000ml/min |
Eluent Concentration Range |
KOH, MSA-0.1 to 100mM |
Concentration Accuracy |
0.1mM |
Original Concentration of Electrolyte |
25% KOH/MSA |
Volume of Electrolyte |
1000mL |
Maximum Working Pressure |
21MPa (3000psi) |
Gradient Accuracy |
1.5% |
Industry Application
Liquid ion concentrations i.e.,drinking water,ground water,factory effluent
Adhesion ion concentrations (extracting adhering ions with pure water)
Ion concentrations in gas (collecting ions in gas with collection liquid)
Send your inquiry directly to us