Wayeal IC6220 Laboratory Test Instruments 21 MPa Ion Chromatography System
Product Introduction
Ion chromatography is used for water chemistry analysis. Ion chromatographs are able to measure concentrations of major anions, such as fluoride, chloride, nitrate, nitrite, and sulfate, as well as major cations such as lithium, sodium, ammonium, potassium, calcium, and magnesium in the parts-per-billion (ppb) range. Concentrations of organic acids can also be measured through ion chromatography.
Product Features
1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.
5. One-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning effect
Product Parameter
Wayeal IC6220 Laboratory Test Instruments 21 MPa Ion Chromatography System | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1.0% |
Pump System | |
Flow Rate | (0.001~10.000) mL/min |
Pump Head Pressure Resistance | (0 ~ 35) MPa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤ 0.0002ug/mL |
Minimum Detection Concentration (Li) | ≤ 0.0001ug/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000 μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5ml standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5uL) |
Syringe Size | Standard: 500ul; optional; 250ul, 1000ul, 2500ul |
Loop Size |
Standard: 100ul; optional: 20ul, 50ul, 200ul |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator |
|
Flow Rate Range | 0.001 to 3.000ml/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21MPa (3000psi) |
Gradient Accuracy | 1.5% |
Industry Application
Some typical applications of ion chromatography include: