Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
GC-FID Total Hydrocarbon Analyzer Air Pollution Monitoring Instruments
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Ambient Air Quality Monitoring Instrument | Packing | Wooden Case Or Customization |
---|---|---|---|
Detection Method | GC-FID | Detection Of Substances | Methane, Non-methane Hydrocarbons |
Detection Limit | ≤20 PpbC | Application | Urban Roads, Airports VOCS Monitoring |
High Light | GC-FID total hydrocarbon analyzer,Air total hydrocarbon analyzer,GC-FID air pollution monitoring instruments |
Ambient Air Quality Monitoring Equipment for Non-methane Total Hydrocarbons Detection
Product Introduction
The continuous ambient air monitoring instruments uses the GC-FID method to directly measure the concentration of methane and non-methane hydrocarbons by back-blowing and enrichment of the sample gas, enabling accurate measurement of low The continuous ambient air non-methane monitoring system uses the GC-FID method to directly measure methane and non-methane concentrations by back-blowing and enrichment of the sample gas. The system operates with a constant flow rate of ambient air into the sampling system. After de-dusting, the sample is enriched and removed at low temperature by a large capacity composite enrichment column, the MFC accumulates the sampling volume, the valve is switched and the back-blowing is performed, resulting in a separate peak of non-methane total hydrocarbons and a direct measurement of the concentration.
Product Performance
1. Accurate determination of total non-methane hydrocarbons in ambient air with detection limits at the ppb level.
2. Low-temperature cold trap enrichment and removal technology to improve the accuracy of direct measurement of non-total methane hydrocarbons
3. Passivation treatment of the internal piping of the instrument, very low adsorption
4. Full cold point free design for non-destructive testing of high boiling points
Product Parameter
Ambient Air Quality Monitoring Instruments |
|
Size |
1030*720*2060mm, 970*900*1000mm |
Working Temperature |
15-35C° |
Measurement Range |
0-5ppm |
Measurement Error |
≤±1% F.S. |
Measurement Method |
GC-FID |
Detection Limit |
≤20 ppb |
Working Humidity |
≤85%RH |
Industry Application