logo

GC-FID Total Hydrocarbon Analyzer Air Pollution Monitoring Instruments

Basic Properties
Place of Origin: Anhui, China
Brand Name: Wayeal
Certification: ISO, CE
Model Number: AQ7800
Trading Properties
Minimum Order Quantity: 1
Price: Negotiation
Payment Terms: L/C,T/T
Supply Ability: 50 Pieces Per Month
Specifications
Product Name: Ambient Air Quality Monitoring Instrument Packing: Wooden Case Or Customization
Detection Method: GC-FID Detection of substances: Methane, Non-methane Hydrocarbons
Detection Limit: ≤20 PpbC Application: Urban Roads, Airports VOCS Monitoring
High Light:

GC-FID total hydrocarbon analyzer

,

Air total hydrocarbon analyzer

,

GC-FID air pollution monitoring instruments

Product Description

Ambient Air Quality Monitoring Equipment for Non-methane Total Hydrocarbons Detection

Product Introduction

The continuous ambient air monitoring instruments uses the GC-FID method to directly measure the concentration of methane and non-methane hydrocarbons by back-blowing and enrichment of the sample gas, enabling accurate measurement of low The continuous ambient air non-methane monitoring system uses the GC-FID method to directly measure methane and non-methane concentrations by back-blowing and enrichment of the sample gas. The system operates with a constant flow rate of ambient air into the sampling system. After de-dusting, the sample is enriched and removed at low temperature by a large capacity composite enrichment column, the MFC accumulates the sampling volume, the valve is switched and the back-blowing is performed, resulting in a separate peak of non-methane total hydrocarbons and a direct measurement of the concentration.

Product Performance

1. Accurate determination of total non-methane hydrocarbons in ambient air with detection limits at the ppb level.
2. Low-temperature cold trap enrichment and removal technology to improve the accuracy of direct measurement of non-total methane hydrocarbons.
3. Passivation treatment of the internal piping of the instrument, very low adsorption.
4. Full cold point free design for non-destructive testing of high boiling points.

Product Parameter

Ambient Air Quality Monitoring Instruments

Size

1030*720*2060mm, 970*900*1000mm

Working Temperature

15-35C°

Measurement Range

0-5ppm

Measurement Error

≤±1% F.S.

Measurement Method

GC-FID

Detection Limit

≤20 ppb

Working Humidity

≤85%RH

Industry Application

Urban air station MHC monitoring,
Urban roads, airports, ports VOCS monitoring
VOCS monitoring at enterprise plant boundaries
Park air VOCS monitoring