Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
IC6200
Wayeal IC Machine Ion Chromatography Instrument for Water Quality analysis
Introduction of Ion Chromatography Instrument
Ion chromatography instrument is a type of high performance liquid chromatograph, so it is also known as high performance ion chromatography (HPIC) or modern ion chromatography. IC systems can analyze particles such as anions, cations, organic salts, and proteins. They are used in environmental, manufacturing, food, pharmaceutical, and chemical industries.
Parameters of Ion Chromatography Instrument
Wayeal IC6200 Series Integrated Anion Or Cation Ion Chromatography System | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | (0.001~10.000)mL/min |
Pump Head Pressure Resistance | (0 ~ 35) MPa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤0.0002μg/mL |
Minimum Detection Concentration (Li) | ≤0.0001μg/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5mL standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5uL) |
Syringe Size | Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size | Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow Rate Range | 0.001 to 3.000ml/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21MPa (3000psi) |
Gradient Accuracy | 1.5% |
Performance of Ion Chromatography Instrument
1. KOH Leaching Solution Generator: A mouse and pure water are all that is needed to produce a constant stream of leaching solution, avoiding errors caused by human preparation of solutions and providing more accurate analytical results.
2. Intergrated design, high brightness LCD full touch GUI controller.
3. Nitrogen pressurisation device: to avoid the introduction of CO2 into the system and to ensure a more stable and accurate system pressure.
4. The full system thermostat and temperature compensation function allows you to carry out your analytical work without the distraction of controlling the temperature conditions in the laboratory and without the need for air conditioning.
5. Stable PEEK pumps that are resistant to corrosion and metal contamination, giving you more stable analysis and longer column service life.
Industry Application
Environment, food, medicine, agriculture, grain and oil, and chemical industry
Send your inquiry directly to us