Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
10.0mg/L~1000.0mg/L Continuous Water Monitoring Equipment System For Dissolved Oxygen
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Water Quality Continuous Monitoring System Equipment | Measurement Range | 10.0~1000.0mg/L |
---|---|---|---|
Measurement Error | ≤±5% | Zero Drift | ≤±5mg/L |
Application | Surface Water | HS Code | 9026809000 |
High Light | 1000.0mg/L Continuous Water Monitoring Equipment,10.0mg/L Continuous Water Monitoring Equipment,10.0mg/L dissolved oxygen monitoring system |
Wastewater Treatment Plants COD Water Quality Continuous Monitoring System Equipment
Product Introduction
The specimen was added with quantitative potassium dichromate solution in strong sulfuric acid medium with silver sulfate as catalyst and mercury sulfate as chloride ion masking agent, and the mixture was confined and dissipated by high temperature and high pressure at 165ºC to quantitatively convert hexavalent chromium to trivalent chromium, and the color of the mixture was changed, and the color change was measured by spectrophotometry to deduce the actual COD value, and the amount of consumed dichromate ions was equivalent to the amount of oxidizable organic matter.
Product Parameter
Wastewater Treatment Plants COD Water Quality Continuous Monitoring System Equipment | |
Measurement methods | Potassium dichromate spectrophotometry |
Measurement range | 10.0~1000.0mg/L |
Error of measurement | ≤±5% |
Zero drift | ≤±5mg/L |
Range drift | ≤±5% |
Repeatability | ≤±3% |
Product Performance
1. Unique three-stage precision photoelectric metering device, fast and accurate reagent extraction, significantly reducing the impact of peristaltic pump tube aging.
2. Precise temperature compensation algorithm and ambient light elimination measures, with consistent accuracy regardless of spring, summer, autumn and winter.
3. Highly reliable reagent selection valve and digestion bottle assembly, with low failure rate and low maintenance workload.
Product Application
Sewage Treatment Plant, Enterprise Outfall