Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
Particulate Matter Air Pollution Instruments For PM10 Pm 2.5 Measurement
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | PM10 Ambient Air Quality Monitoring Instruments | Sampling Flow Rate | 16.67L/min |
---|---|---|---|
Ambient Humidity Accuracy | ±4% | Radioactive Light Sources | C14(100uCi) |
Detection Limit | 2μg/m³ | Operating Interface | Touch Screen |
High Light | PM10 air pollution instruments,Pm2.5 air pollution instruments,PM10 pm 2.5 instrument |
PM 2.5 PM 10 Particulate Ambient Air Quality Monitoring Instruments
Product Introduction
Product Performance
2. Dynamic heating to reduce the loss of volatile particulate matter.
3. Automatic elimination of interference from radioactive substances in the ambient air.
Product Parameter
Product Name | PM10 Ambient Air Quality Monitoring Instruments |
Test Item | TSP,PM10,PM2.5 |
Test principles | Beta Ray Attenuation Method |
Range | (0-1000,0-10000) μg/m³ |
Minimum Uisplay Unit | 0.1μg/m³ |
Sampling Flow Rate | 16.67L/min |
Detection Limit | 2μg/m³ |
Ambient Temperature Accuracy | ±2℃ |
Ambient Humidity Accuracy | ±4% |
Radioactive Light Sources | C14(100uCi) |
Zero Drift | ±2%FS |