Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
OEM Total Nitrogen Analyzer Drinking Water Quality Monitoring System 5000mg/L
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Continuous Nitrogen Water Quality Monitoring Equipment Online Automatic Monitor | Product Size | 380*470*600mm |
---|---|---|---|
Weight | 25KGS | Measurement Range | 0-5000mg/L |
Detection Limit | 3mg/L | Measurement Error | ≤±5% |
High Light | OEM total nitrogen analyzer,5000mg/L total nitrogen analyzer,5000mg/L drinking water quality monitoring system |
WS1503 Continuous Nitrogen Water Quality Monitoring Equipment Online Automatic Monitor
Product Introduction
In the presence of alkaline medium and sodium nitrite ferrocyanide (sodium nitroprusside), ammonium reacts with salicylate and hypochlorite ions to form a water-soluble blue compound with maximum absorption at 697 nm, and the amount of ammonia nitrogen in the water sample is measured by photoelectric colorimetry according to the Lambert-Bier law. A specific masking agent was added to remove the interference of cations (especially calcium and magnesium ions).
Product Parameter
Product Name | Continuous Nitrogen Water Quality Monitoring Equipment Online Automatic Monitor |
Measurement Method | Salicylic Acid Spectrophotometric Method |
Measurement Error | ≤±3% |
Zero Drift | Zero-point Drift |
Measurement Range | 0~300.0mg/L |
Repeatability | ≤±2% |
Range Drift | ≤±1% |
Product Performance
1. Unique three-stage precision photoelectric metering device, fast and accurate reagent extraction, significantly reducing the
2. Impact of peristaltic pump tube aging.
3. Precise temperature compensation algorithm and ambient light elimination measures, with consistent accuracy regardless of spring, summer, autumn and winter.
Product Application
Sewage Treatment Plant, Enterprise Outfall