logo

HPLC High Performance Liquid Chromatography Instrument For Aflatoxin Analysis

Basic Properties
Place of Origin: Anhui, China
Brand Name: Wayeal
Certification: ISO, CE
Model Number: LC3200S
Trading Properties
Minimum Order Quantity: 1
Price: Negotiation
Payment Terms: L/C, T/T
Supply Ability: 50pcs/month
Specifications
Product Name: Liquid Chromatography Instrument Detector: UVD/ELSD/DAD/FLD/RID
Working Power Supply: 220V, 50Hz Ambient Temperature: 10-40°C
Relative Humidity: 20~85% Qualitative Repeatability: ≤0.2%
High Light:

HPLC Liquid Chromatography Instrument

,

hplc machine for Aflatoxin Analysis

,

Aflatoxin Analysis Liquid Chromatography Instrument

Product Description

HPLC Cromatografía High Performance Liquid Chromatography Instrument for Aflatoxin Analysis
Description of High Performance Liquid Chromatography Instrument

HPLC is an analytical chemistry technique applied to separate, identify, and quantify semi- and non-volatile compounds in liquid samples. Industries like pharma and biopharma, environmental, and food and beverage use HPLC for the characterization, purification, and quantitation of compounds. An HPLC instrument has four major components: a pump to deliver the mobile phase, an autosampler to inject the sample, a stationary phase column to separate the sample compounds, and a detector to measure the compounds. Additional elements include connective capillaries and tubing to allow the continuous flow of the mobile phase and sample through the system and a CDS package to control the HPLC instrument, separation, detection, and result evaluation.

Technical Data of High Performance Liquid Chromatography Instrument

HPLC Cromatografía High Performance Liquid Chromatography Instrument for Aflatoxin Analysis

Working Conditions

 
Working Power Supply 220V,50Hz
Ambient Temperature 10-40℃
Ambient Humidity 20-85% relative humidity(non-condensing)

System features

 
Qualitative Repeatability RSD≤0.2%
Quantitative Repeatability RSD≤0.4%
High Pressure Pump  
Flow Rate Range 0.0001-10.000mL/min( increments: 0.0001mL/min)
Setting Step 0.001mL/min
Pressure Range 0~45MPa
Pressure Pulsation 0.1MPa(10MPa, C18, methanol 1mL/min)
Flow Rate Set Error ±0.2%
Flow Rate Set Stability RSD≤0.06%
Gradient Error

±1%

Column Oven  
Temperature Control Range 4~85°C
Temperature Stability ±0.02°C
Temperature Setting Resolution 0.1°C
Autosampler  
Injection Volume Repeatability <0.5%RSD
Linearity >0.9999
Injected Volume Accuracy Error ±1%
Cross Contamination <0.002%
Number of Smaples 120(2*20,2mL)
Injection Volume 1-100μL