Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
CE
Model Number:
TQ9200
TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System
Introduction of LC-MS/MS
The system consists of the LC3600 ultra-high-performance liquid chromatograph and the TQ9200 triple quadrupole mass spectrometer. It incorporates core technologies such as an ultra-high-pressure direct-drive pump, ultra-high-pressure needle-in-flowpath lossless injection, an actively preheated column oven, a highly stable EI source, a high-durability vacuum interface, high-efficiency ion transfer lenses, and a tandem quadrupole high-stability drive system. These innovations collectively deliver stable, sensitive, and durable instrument performance.
Technical Parameters of TQ9200
Working conditions |
|
Working power supply |
220V±22V, 50Hz±0.5Hz |
Ambient temperature |
15-30°C |
Relative humidity |
not more than 80% |
UHPLC |
|
Pump drive mode |
linear motor pump |
Gradient mode |
binary (4-waysolvent) |
Flow rate setting range |
0.001-2.000mL/min |
Flow rate setting increment |
0.001mL/min |
Maximumoperating pressure |
150MPa |
Degassing |
5-channel online degassing |
Autosampler |
|
Maximumwithstand pressure |
150MPa |
Sampling volume range |
0.1-20.0μL (50μL optional) |
Linearity |
R≥0.9999 |
Cross-contamination |
<0.004 % |
Number of samples |
108 (2*54,2 ml), supports 96 shallow well plate, 96 deep well plate, 384 well plate |
Temperature setting range |
4.0~40.0 ℃ (optional refrigeration) |
Temperature stability |
±2 ℃ |
Feed rate |
12s |
Column temperaturechamber |
|
Temperature setting range |
20.0-90.0 ℃ |
Temperature stability |
±0.02 ℃/h |
Temperature setting value error |
± 0.1 ℃ |
Triple quadrupole mass spectrometer |
|
Mass analysis range |
5-1250 |
Scanning speed |
12000 Da/s |
Mass resolution |
0.6-0.8 Da (609 mass peaks) |
Linearity range |
≥1E4 |
Mass accuracy |
0.1 Da |
Massstability |
0.1 Da/24h |
Limit of detection (rifampicin) |
0.1pg |
Sensitivity |
S:N >20w:1 on a 1pg Risperdal column |
System indicators |
|
Qualitative reproducibility |
RSD≤5% |
Quantitative reproducibility |
RSD≤5% |
Applications of LC-MS/MS
Forensic Safety
Detection of Toxicants (Drugs) in Blood and Urine
Rapid Identification of Drug Impurities
Illegally Adulterated Chemicals in Pharmaceuticals
Food Safety
Determination of Aflatoxin M-group in Dairy Products
Analysis of 204 Pesticide Residues in Tea
Detection of 76 Veterinary Drug Residues in Animal-derived Foods
Environmental Monitoring
Phenoxy Acid Herbicides in Water
Polycyclic Aromatic Hydrocarbons (PAHs) in Electrical and Electronic Products
Sulfonylurea Herbicide Residues in Soil
Send your inquiry directly to us