Dual System Ion Chromatography Instrument for Anions or Cations Analysis Simultaneously
Introduction of Ion Chromatography Instrument
Ion chromatocraphy is positioned as a type of liquid chromatography that measures ionic species components. This method separates ion species components in a sample solution in a packed column using an eluent as the mobile phase and an ion exchanger as the stationary phase. Electroconductivity detectors are commonly used to detect ionic species, but for some purposes, ultraviolet-visible spectrophotometry and electrochemical detectors are used as well as liquid chromatography.
Features of Ion Chromatography Instrument
1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives;
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time;
5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.
Product Parameter
In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | (0.001~10.000)mL/min |
Pump Head Pressure Resistance | (0 ~ 35) Mpa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤0.0002μg/mL |
Minimum Detection Concentration (Li) | ≤0.0001μg/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5mL standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5μL) |
Syringe Size | Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size | Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow Rate Range | 0.001 to 3.000mL/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21Mpa (3000psi) |
Gradient Accuracy | 1.5% |
Ion Chromatograpny Instrument Applized in Water Quality Control
Quality control for environmental water and wastewater, as well as air quality measurement and quality control in the food field, in view of its ability to perform simultaneous multi-component analysis and its difficulty in being affected by coexisting components. In addition, in addition to inorganic cations and anions, the components to be measured include lower amines, heavy metal ions, organic acids, and saccharides, and the scope of application has expanded.
Send your inquiry directly to us