Wayeal Flame Atomic Absorption Spectroscopy AAS For Metal Analysis

Wayeal Flame Atomic Absorption Spectroscopy AAS For Metal Analysis

Wayeal Flame Atomic Absorption Spectroscopy

Metal Analysis Flame Atomic Absorption Spectroscopy

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO

Model Number:

AA2300

Contact Us
Request A Quote
Product Details
Product Name:
AAS Atomic Absorption Spectroscopy Machines
Models:
AA2300
Wavelength Range(nm):
185-910nm
Wavelength Indication Error(nm):
±0.15nm
Wavelength Repeatability(nm):
≤0.05nm
Spectral Bandwidth:
0.1, 0.2, 0.4, 1.0, And 2.0nm
Highlight:

Wayeal Flame Atomic Absorption Spectroscopy

,

Metal Analysis Flame Atomic Absorption Spectroscopy

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
Wooden Case
Delivery Time
35 days
Supply Ability
30 Pieces Per Month
Product Description

Wayeal Flame Atomic Absorption Spectroscopy AAS Atomic Absorption Spectrophotometer Machine for Metal Analysis
 
Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectrophotometry analyzes the concentration of elements in a liquid sample based on energy absorbed from certain wavelengths of light (usually 185 to 900nm). Atomic absorption spectrophotometers typically include a flame burner to atomize the sample (most commonly a hollow cathode lamp), a monochromator and a photon detector. Depending on the model, some atomic absorption spectrometers are equipped with a turret or fixed lamp socket that can hold multiple lamps (up to eight) to reduce downtime between samples or allow for sequential analysis.

Technical Datas of Atomic Absorption Spectrophotometer AA2300

Wayeal Flame Atomic Absorption Spectroscopy AAS For Metal Analysis
Wavelength range(nm) 185-900nm
Wavelength indication error(nm) ±0.15nm
Wavelength repeatability(nm) ≤0.05 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift ±0.002/30min
Instantaneous noise(Abs) ≤0.002 Abs
Flame Atomizer  
Detection limit Cu: ≤0.002μg/mL
Repeatability RSD≤0.25%
Graphite Furnace Atomizer  
Detection limit(Graphite Furnance: Cd pg) ≤0.3pg
Repeatability RSD≤1.5 %
Heating temperature room temperature -3000°C or so
Heating rate 3000°C/s
Autosampler  
Injection bits 108
Linear >0.999
Injection volume 1-200μL
Injection volume repeatability ≤0. 1%
Result repeatability ≤1.5%
Background correction Deuterium lamp
Lamp position 8

 
Features of Atomic Absorption Spectrophotometer AA2300

1. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
2. Full-reflection dual-beam optical path, high optical path stability
3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
4. 8 lamp holders preheat simultaneously to improve detection efficiency
 
Applications of Atomic Absorption Spectrophotometer

Foods and Beverages – In synthetic processed foods, metal pickup takes place due to contact with processing equipment and catalytic conversions. Consumer awareness on food safety is increasing by the day so manufacturers have to ensure that the trace metals do not exceed the permissible limits and this requires rigorous quality control through atomic absorption spectroscopy and other sophisticated instruments.

Oil and Petroleum – Both edible oils and mineral oils require refining before consumption. Such refining operation can involve distillation as well as catalytic refining. Uptake of metals during such operations can lead to deterioration of performance or consumer hazards. Trace metal analysis of engine oil provides useful diagnostic information on the wear and tear of engine parts. 

Agriculture – Trace metal constitution of soils in addition to their acidic or basic nature is essential to establish their productivity and nutrient value. Trace metal composition of plants (leaves, stems and roots) gives a fair idea on how the uptake of minerals gets distributed under different growth conditions  

Forensics – Trace metal analysis provides valuable information on specimens such as stomach contents for food poisoning, paint chips, fibres and hair strands collected from the scene of a crime.

Wayeal Flame Atomic Absorption Spectroscopy AAS For Metal Analysis 0Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 2Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 3Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 4Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 5Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 6Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 7