190 - 800nm DAD Detector Equipped HPLC Instrument Of Trace Components Analysis

Place of Origin Anhui, China
Brand Name Wayeal
Certification ISO, CE
Model Number LC3200
Minimum Order Quantity 1
Price Negotiation
Packaging Details One piece per wooden case
Delivery Time 20 days
Payment Terms L/C, T/T
Supply Ability 30 Pieces Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name High Pressure Pump HPLC Instruments Detector DAD Detector
Wavelength Length 188 - 800 Nm Wavelength Error ≤ ±1.0 Nm
Baseline Noise 6× 10-5 AU Baseline Drift 1 × 10-3 AU/h
High Light

DAD Detector Equipped HPLC Instrument

,

190nm High Performance Liquid Chromatography Instrument

,

800nm HPLC Instrument

Leave a Message
Product Description

190-800nm DAD Detector Equipped High Performance Liquid Chromatography Instrument of Trace Components Analysis
 
Product Description

 

High-pressure liquid chromatography or high-performance liquid chromatography (HPLC) is known as a specialized technique in which columns as well as liquid chromatography are used in the separation, characterization, amount and investigation of the active moieties existing in the mixture. When compared to other traditional techniques, HPLC has significantly improved performance. The expansion of HPLC has evolved from conventional column chromatography and its performance (efficiency, resolution), which was enhanced using a stationary phase composed of spherical particles of a diameter range of 2 µm to 5 µm. Therefore, owing to the small particles, the head pressure forces the solvent or mobile liquid to pass through the column at high pressure. That’s why it is known as high-pressure liquid chromatographyHPLC technique is applied for the separation of not only volatile compounds but also ionic species, polymeric materials, labile natural products, and macromolecules as well as high molecular weight functional groups

 

Product Parameter

 

190 - 800nm DAD Detector Equipped High Performance Liquid Chromatography Instrument of Trace Components Analysis
Pump  
Gradient Quadratic Low Pressure
Flow Rate Range 0-11.0000mL/min
Min Injection Unit 0.0001mL/min
Flow Rate Error ±0.2%
Flow Rate Repeatability ≤ 0.08% RSD
Gradient Stability < 0.5% RSD
Max Operating Pressure 42MPa
In-line Degassing  
Column Oven  
Temperature Range 4 ℃ ~ 85 ℃
Temperature Stability ≤±0.02 ℃
Autosampler  
Sampling Volume 0.1-20.0uL (in 0.1μL increments)
Sample Capacity 120 vials, 2ml vial
Linearity r > 0.9999
Cross-contamination < 0.002%
Sampling Error ±0.2μL (sampling volume 10μL)
Sampling Repeatability < 0.3% RSD
Injection Speed 15s
DAD Detector  
Wavelength Range 188 - 800 nm
Wavelength Error ≤ ±1.0 nm
Wavelength Repeatability ≤ ±0.1 nm
Baseline Noise 6× 10-5 AU
Drift 1 × 10-3 AU/h
Linearity 2.0 AU

 
 
Product Performance
 
1. Two optional modes: binary high pressure and quaternary low pressure. The binary high pressure mode is equipped with a solvent selector valve, which can be extended from binary to quaternary system, greatly improving the flexibility of system configuration.

 

2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.

 

3. A variety of detectors available, such as DAD, ELSD and FLD.

 

4. Dual-wavelength detection, two wavelengths canbe detected at the same time. 

 

 

Product Application
 
 

  • Water purification
  • Detection of impurities in pharmaceutical industries
  • Pre-concentration of trace components
  • Ligand-exchange chromatography
  • High-pH anion-exchange chromatography of carbohydrates and oligosaccharides


190 - 800nm DAD Detector Equipped HPLC Instrument Of Trace Components Analysis 0
 

190 - 800nm DAD Detector Equipped HPLC Instrument Of Trace Components Analysis 1

 

190 - 800nm DAD Detector Equipped HPLC Instrument Of Trace Components Analysis 2

 

190 - 800nm DAD Detector Equipped HPLC Instrument Of Trace Components Analysis 3