Specifications
Product Name: Liquid Chromatography Instrument Detector: UVD/DAD/ELSD/FLD/RID
Column Temperature Range: 5 °C ~ 85 °C Syringe: 250μL( Standard, With 500μL,1000μL, 2500μL Optionals)
Sample Loop: 20μL( Standard, With 50μL, 100μL, 200μL Optional) Noise: 1.5×10-5Au
High Light:

Modular Liquid Chromatography Instrument

,

Hplc Liquid Chromatography 42MPa

,

220V 50HZ Liquid Chromatography Instrument

Product Description

220V 50Hz 42MPa Modular Design HPLC Chromatografia High Efficiency Liquid Chromatography Instrument
Description of HPLC Liquid Chromatography Instrument

High-performance liquid chromatography (HPLC) is a form of liquid chromatography to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of mobile phase, a pump, an injector, a separation column, and a detector. Compounds are separated by injecting a plug of the sample mixture onto the column.The different components in the mixture pass through the column at different rates due to differences in their partitioning behavior between the mobile liquid phase and the stationary phase.

Parameters of Liquid Chromatography Instrument

220V 50HZ 42MPa Modular Design HPLC Chromatografia High Efficiency Liquid Chromatography Instrument
Physical Specification  
Power Requirements 220V,50Hz
Ambient Temperature 4-40℃
Ambient Humidity 20-85% relative humidity(non-condensing)
System  
Qualitative repeatability(Retention time) RSD≤0.3%
Quantitative repeatability(Area) RSD≤0.6%
Pump  
Flow Rate Range 0.0001-10.000mL/min( increments :0.0001 mL/min)
Max Operating Pressure 45MPa
Pressure Pulsation <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Accuracy ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Precision RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient Accuracy ±1%
Column Oven  
Temperature Setting Range 5 °C ~ 85 °C
Temperature Stability ≤0.2°C/h
Temperature Controlling Precision ±0.1 °C
Autosampler  
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity >0.999
Cross Contamination(Carry Over) <0.01%
Sample Capacity 120 Samples( 1.5ml vials)
Syringe 250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop 20μL( Standard, with 50μL, 100μL, 200μL optional)

DAD Detector

 
Noise 1.5×10-5Au
Drift ≤1×10-3Au/h
LOD 5.0×10-9g/mL (naphthalene/methanol)
Wavelength Range 190-800nm
Wavelength Reproducibility ≤±0.1 nm
Linearity ≥1.0×104