HPLC Chromatografia Aflatoxin Analysis High Pressure Liquid Chromatography Equipment
Description of HPLC Liquid Chromatography Instrument
High-performance liquid chromatography (HPLC), formerly referred to as high-pressure liquid chromatography, is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture. HPLC has been used for manufacturing (e.g., during the production process of pharmaceutical and biological products), legal (e.g., detecting performance enhancement drugs in urine), research (e.g., separating the components of a complex biological sample, or of similar synthetic chemicals from each other), and medical (e.g., detecting vitamin D levels in blood serum) purposes.
Parameters of HPLC Liquid Chromatography Instrument
Manufacturer: | Wayeal |
Product Name: | Liquid Chromatography Instrument |
Working Power Supply | 220V, 50Hz |
Ambient Temperature | 10~40°C |
Relative Humidity | 20~85% |
Qualitative Repeatability | ≤0.2% |
Quantitative Repeatability | ≤0.4% |
High Pressure Constant Flow Pump | |
Flow Rate Range | 0.001~10.000mL/min |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa |
Flow Rate Set Error | ±0.2% |
Flow Rate Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Cross Contamination | <0.002% |
Injection Volume Accuracy Error | ±1% |
Sample Positions | 120 |
Injection Volume | 1~100μL |
UV Detector | |
Baseline Noise | ≤2.0*10-6Au |
Baseline Drift | ≤1*10-5Au/h |
Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
Spectral Range | 188~900nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥103 |
DA Detector | |
Baseline Noise | ≤4*10-5Au |
Baseline Drift | ≤3*10-5Au/h |
Mini Detection Concentration | ≤2*10-8g/mL |
Spectral Range | 190~800nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥ 104 |
ELS Detector | |
Baseline Noise | ≤ 0.0037mV |
Baseline Drift | ≤ 0.0026mV/30min |
Evaporation Gas Flow Range | (0 ~ 3) SLM |
Atomization Temperature Range | Room temperature ~ 90℃ |
Evaporation Temperature Range | Room temperature~110℃ |
Detection Chamber Temperature Range | Room temperature~60℃ |
Input Air Pressure | (4 ~ 7) bar |
FL Detector | |
Baseline Noise | ≤ 5×10-6 FU |
Baseline Drift | ≤ 2 × 10-5 FU/30min |
Spectral Range | (200 ~ 650) nm |
Wavelength Error | ± 0.1 nm |
Linearity Range | ≥ 104 |
RI Detector | |
Detection Range | 0.25 ~ 512 μRIU |
Linearity Range | ≥ 600 μRIU |
Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
Cell Volume | 8μL |
Performance of HPLC Liquid Chromatography Instrument
1. Mainstream split design, complete system testing function, to meet most testing needs
2. The new cam curve design adopts electronic pulsation suppression technology and solvent
3. Compression compensation to further reduce pressure fluctuations and ensure higher repeatability of test results.
4. Optional UV, ELSD, FLD and DAD detectors.