Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
LC3600
Extremely Low Cross-contamination UHPLC Ultra-high Performance High Pressure Liquid Chromatography Equipment 150MPa
Description of Ultra High Performance Liquid Chromatography Instrument
UHPLC has been gradually adopted in industrial labs, especially the pharmaceutical industry dueto its high resolution, high speed, and solvent saving, since its introduction in early 2004. A UHPLC method using a sub-2 um column could reduce the analysis time by up to 80% and savethe mobile phase consumption by at least 80% compared with an HPLC method using aconventional 3.5 um column without sacrificing separation performance. In addition, the muchshorter run time significantly reduces UHPLC method development scouting time. It has the characteristics of high-precision ultra-high pressure infusion unit, low system diffusion volume and optimized extremely low cross-contamination.
Parameters of Ultra High Performance Liquid Chromatography Instrument
Extremely Low Cross-contamination UHPLC Ultra-high Performance High Pressure Liquid Chromatography Equipment 150MPa | |
Work Power |
220V, 50HZ |
Ambient Temperature | 10-~40°C |
Relative Humidity | 20-85% |
System Indicators | |
Qualitative Repeatiblity | RSD ≤0.1% |
Quantitative Repeatability | RSD ≤0.3% |
High Pressure Constant Current Pump | |
Pump Drive Mode | Linear Motor Pump |
Gradient Mode | Binary (4-way solvent) |
Flow Setting Range | 0.0001~2ml/min |
Flow Setting Increment | 0.001ml/min |
Max Operating Pressure | 150MPa |
Flow Setting Error | ±1.1% |
Flow Stability | ≤0.09% RSD |
Gradient Stability | ≤0.02% RSD |
Column Oven | |
Temperature Setting Range | 20~90°C |
Temperature Stability | ± 0.3°C/h |
Error of Temperature Setting Value | ± 0.5°C |
Autosampler | |
Maximum Withstand Pressure | 150MPa |
Injection Volumn Range | 0.1~10ul |
Injection Volume Error | ± 0.2ul (Injection Volume 10ul) |
Injection Repeatability | < 0.3% RSD |
Linearity | R≥0.999 |
Cross-contamination | < 0.001% |
Number of Smples | 96 Vials (2*48, 2ml) |
Temperature Seting Range | 4~40 °C |
Temperature Stability | ± 1°C |
Sampling Speed | 15s |
Ultra-efficient DAD Detector | |
Baseline Noise | ≤10-6 AU |
Baseline Drift | ≤0.9x10-3 AU/h |
Minimum Test Concentration |
2×10-9g/ml (naphthalene/methanol) |
Wavelength Range | 190~800nm |
Wavelength Indication Error | ≤ ±1nm |
Wavelength Repeatability | ≤ ± 0.1nm |
Linear | 2.0 AU |
Sampling Rate | Up to 100Hz |
Number of Arrays | 1024 |
Light Source | Deuterium (D2) Lamp |
Performance of Ultra High Performance Liquid Chromatography Instrument
1. The dynamic compression compensation of the ultra-efficient binary high-pressure pump adpots high-precision real-time pressure following technology to achieve the effect of "zero fluctuation" and bring extremely high flow stability.
2. The ultra-efficient autosampler adpots ultra-high pressure needle in the flow path non-destructive sampling technology, with a very low sampling cycle period.
3. Needle-in-flow autosampler with ultra-low injection cycle time
4. Extremely low cross-contamination
5. Active preheat function, fast warming rate
Send your inquiry directly to us