• Anhui Wanyi Science and Technology Co., Ltd.
    F*Corp
    I was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
  • Anhui Wanyi Science and Technology Co., Ltd.
    A*A.S
    I enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
  • Anhui Wanyi Science and Technology Co., Ltd.
    T*Sp
    I purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
Contact Person : Larry
Phone Number : +8613586823203
Whatsapp : +8613586823203

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa

Place of Origin Anhui, China
Brand Name Wayeal
Certification ISO, CE
Model Number LC3600
Minimum Order Quantity 1
Price Negotiation
Packaging Details One piece per wooden case
Delivery Time 20 days
Payment Terms L/C, T/T
Supply Ability 30 Pieces Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name Ultra-high Performance High Pressure Liquid Chromatography Temperature Setting Range 20 °C~90℃
Temperature Stability ±0.3℃/h Injection Repeatability <0.3 %RSD
Cross-contamination <0.001% Baseline Noise ≤7× 10-6 AU
High Light

Low Cross Contamination UHPLC Equipment

,

High Pressure Liquid Chromatography Equipment 150MPa

,

150 MPa UHPLC Equipment

Leave a Message
Product Description

Extremely Low Cross-contamination UHPLC Ultra-high Performance High Pressure Liquid Chromatography Equipment 150MPa
 
Product Description

 

UHPLC has been gradually adopted in industrial labs, especially the pharmaceutical industry dueto its high resolution, high speed, and solvent saving, since its introduction in early 2004. A UHPLC method using a sub-2 um column could reduce the analysis time by up to 80% and savethe mobile phase consumption by at least 80% compared with an HPLC method using aconventional 3.5 um column without sacrificing separation performance. In addition, the muchshorter run time significantly reduces UHPLC method development scouting time. It has the characteristics of high-precision ultra-high pressure infusion unit, low system diffusion volume and optimized extremely low cross-contamination. 

 

Product Parameter

 

Extremely Low Cross-contamination UHPLC Ultra-high Performance High Pressure Liquid Chromatography Equipment 150MPa
Work Power

220V, 50HZ

Ambient Temperature 10-~40°C
Relative Humidity 20-85%
System Indicators  
Qualitative Repeatiblity  RSD ≤0.1%
Quantitative Repeatability RSD ≤0.3%
High Pressure Constant Current Pump  
Pump Drive Mode Linear Motor Pump
Gradient Mode Binary (4-way solvent)
Flow Setting Range 0.0001~2ml/min
Flow Setting Increment 0.001ml/min
Max Operating Pressure 150MPa
Flow Setting Error ±1.1%
Flow Stability ≤0.09% RSD
Gradient Stability  ≤0.02% RSD
Column Oven  
Temperature Setting Range 20~90°C
Temperature Stability  ± 0.3°C/h
Error of Temperature Setting Value ± 0.5°C
Autosampler  
Maximum Withstand Pressure 150MPa
Injection Volumn Range 0.1~10ul
Injection Volume Error ± 0.2ul (Injection Volume 10ul)
Injection Repeatability  < 0.3% RSD
Linearity R≥0.999
Cross-contamination < 0.001%
Number of Smples 96 Vials  (2*48, 2ml)
Temperature Seting Range 4~40 °C
Temperature Stability ± 1°C
Sampling Speed 15s
Ultra-efficient DAD Detector  
Baseline Noise ≤10-6 AU
Baseline Drift ≤0.9x10-3 AU/h
Minimum Test Concentration 

2×10-9g/ml (naphthalene/methanol)

Wavelength Range 190~800nm
Wavelength Indication Error ≤ ±1nm
Wavelength Repeatability ≤ ± 0.1nm
Linear 2.0 AU
Sampling Rate Up to 100Hz
Number of Arrays 1024
Light Source Deuterium (D2) Lamp

 
Product Performance
 
1. The dynamic compression compensation of the ultra-efficient binary high-pressure pump adpots high-precision real-time pressure following technology to achieve the effect of "zero fluctuation" and bring extremely high flow stability. 

 

2. The ultra-efficient autosampler adpots ultra-high pressure needle in the flow path non-destructive sampling technology, with a very low sampling cycle period. 

 

3. Needle-in-flow autosampler with ultra-low injection cycle time

 

4. Extremely low cross-contamination

 

5. Active preheat function, fast warming rate

 

Product Application

 
Food, medicine, environment, agriculture and scientific research

 
UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 0
 

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 1

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 2

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 3

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 4

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 5

UHPLC Ultra High Performance High Pressure Liquid Chromatography Equipment 150MPa 6