Flame Atomic Absorption Spectrophotometer AAS Lab Analysis Instrument

Flame Atomic Absorption Spectrophotometer AAS Lab Analysis Instrument

Lab Analysis Atomic Absorption Spectrophotometer AAS

ISO Atomic Absorption Spectrophotometer AAS

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO

Model Number:

AA2300

Contact Us
Request A Quote
Product Details
Wavelength Range:
185-910nm
Spectral Bandwidth:
0.1, 0.2, 0.4, 1.0, And 2.0nm
Zero Drift(Abs/30min):
±0.0015nm
Linearity:
>0.999
Product Name:
AA2300 Atomic Absorption Spectrophotometer
Repeatability(Flame RSD%):
≤0.05nm
Highlight:

Lab Analysis Atomic Absorption Spectrophotometer AAS

,

ISO Atomic Absorption Spectrophotometer AAS

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
Wooden Case
Delivery Time
30 days
Supply Ability
30 Pieces Per Month
Product Description

Lab Analysis Instrument Flame Atomic Absorption Spectrophotometer AAS
 
Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectrometer is used to analyzes metal elements according to the effect of atomic vapor in the ground state of matter on characteristic radiation absorption, and it can sensitively and reliably determine minor or trace elements.
 
Parameters of Atomic Absorption Spectrophotometer AA2300

Flame Atomic Absorption Spectrophotometer AAS Lab Analysis Instrument
Wavelength range(nm) 185-900nm
Wavelength indication error(nm) ±0.15nm
Wavelength repeatability(nm) ≤0.05 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift ±0.002/30min
Instantaneous noise(Abs) ≤0.002 Abs
Flame Atomizer  
Detection limit Cu: ≤0.002μg/mL
Repeatability RSD≤0.25%
Graphite Furnace Atomizer  
Detection limit(Graphite Furnance: Cd pg) ≤0.3pg
Repeatability RSD≤1.5 %
Heating temperature room temperature -3000°C or so
Heating rate 3000°C/s
Autosampler  
Injection bits 108
Linear >0.999
Injection volume 1-200μL
Injection volume repeatability ≤0. 1%
Result repeatability ≤1.5%
Background correction Deuterium lamp
Lamp position 8

 
Features of Atomic Absorption Spectrophotometer AA2300
1. Very low stray light, high detection sensitivity
2. Full-reflection dual-beam optical path, high optical path stability
3. Flame-graphite furnace integrated design
4. 8 lamp holders preheat simultaneously to improve detection efficiency

5.  Combustion head: all- titanium metal titanium combustion head

Applications of Atomic Absorption Spectrophotometer
Atomic absorption spectroscopy is frequently utilized in agriculture and the study of environmental sciences. Atomic absorption spectroscopy, which analyzes the light emitted from a sample rather than the light absorbed—are frequently used in various fields of agricultural study. Typically, they’re used to identify and analyze the presence of potentially harmful elements in the environment.

Atomic absorption spectroscopy has been utilized in the study of forensic sciences for many years. Common causes of metal poisoning, such as mercury and lead, are easily detectable using this technology and can be identified even in trace amounts.
Flame Atomic Absorption Spectrophotometer AAS Lab Analysis Instrument 0Flame Atomic Absorption Spectrophotometer AAS Lab Analysis Instrument 1Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 2Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 3Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 4Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 5Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 6Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 7