• Anhui Wanyi Science and Technology Co., Ltd.
    F*Corp
    I was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
  • Anhui Wanyi Science and Technology Co., Ltd.
    A*A.S
    I enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
  • Anhui Wanyi Science and Technology Co., Ltd.
    T*Sp
    I purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
Contact Person : Larry
Phone Number : +8613586823203
Whatsapp : +8613586823203

Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis

Place of Origin Anhui, China
Brand Name Wayeal
Certification ISO, CE
Model Number AA2210
Minimum Order Quantity 1
Price Negotiation
Packaging Details One piece per wooden case
Delivery Time 25 days
Supply Ability 20 Pieces Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Wavelength Range 185-900 Resolution(%) ≤25
Zero Drift(Abs/30min) ±0.002 Linearity Error(%) ≤10
Product Name Graphite AAS Spectrophotometer Repeatability(Flame RSD%) ≤0.2
High Light

Double Beam AAS Atomic Absorption Spectrometer

,

Graphite AAS Atomic Absorption Spectrometer

,

Double Beam Graphite AAS Spectrophotometer

Leave a Message
Product Description

Double Beam Graphite AAS Atomic Absorption Spectrometer for Metal Analysis
 
Product Introduction
Atomic absorption spectrometer will be used to analyzes metal elements according to the effect of atomic vapor in the ground state of matter on characteristic radiation absorption, and it can sensitively and reliably determine minor or trace elements.
 
Product Parameter

 

Double Beam Graphite AAS Atomic Absorption Spectrometer for Metal Analysis
Wavelength range(nm) 185-900
Wavelength indication error(mm) ±0.25
Wavelength repeatability(nm) ≤0.1
Broadband deviation(nm) ±0.02
Resolution(%) ≤25
Instantaneous noise(Abs) ±0.0025
Zero drift(Abs/30min) ±0.002
Boundary energy:instantaneous noise(Abs) ≤0.02
Detection limit(Flame:Cu ug/mL)) ≤0.002
Apparent atomization rate(%) ≥8
Detection limit(Graphite Furnance: Cd pg) ≤0.3
Repeatability(Flame RSD%) ≤0.2
Repeatability(Graphite Furnance RSD%) ≤1.5
Linearity error(%) ≤10
Background correction capability ≥60

 
Product Features


1. Very low stray light, high detection sensitivity


2. 25% increase in high luminous flux


3. Flame-graphite furnace integrated design


4. High adaptability and expandability

 
Product Application
Food, medicine, environment, metallurgy, agriculture and disease control
 
 
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 0
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 1

Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 2
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 3
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 4
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 5