logo
Home > products > Liquid Chromatography Instrument >
Flow to Needle High Performance Liquid Chromatography Instrument With Binary Pump

Flow to Needle High Performance Liquid Chromatography Instrument With Binary Pump

150MPa UHPLC Machine

150MPa Ultra High Performance Liquid Chromatography

UHPLC Machine With Binary Pump

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO, CE

Model Number:

LC3400

Contact Us
Request A Quote
Product Details
Product Name:
Liquid Chromatography Instruments
Number Of Arrays:
1024
Warranty:
1 Year
Power Supply:
220V 50HZ
Ambient Temperature:
10-40℃
Light Source:
Deuterium (D2) Lamp
Highlight:

150MPa UHPLC Machine

,

150MPa Ultra High Performance Liquid Chromatography

,

UHPLC Machine With Binary Pump

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
Wooden Case
Delivery Time
30 days
Payment Terms
L/C, T/T
Supply Ability
30 Pieces Per Month
Product Description

Techncial Data of LC3400  High Performance Liquid Chromatography Instrument

Product Name

LC3400 Liquid Chromatography Instrument

Maximum Operating Pressure

62MPa/75MPa

Flow Rate Setting Range

0.0000~12.0000mL/min

Flow Rate Setting Increment

0.0001mL/min

Gradient Error

≤ 0.75%

Gradient Stability

0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)

Flow Rate Setting Value Error

±0.20%

Flow Rate Stability

≤0.075% RSD

Autosampler

 

Injection Volume

100μL, 200μL, 500μL, 1000μL, 1500μL, 2000μL

Repeatability

<0.3%RSD (2μL~Max),

<1.0%RSD (0.1μL~1.9μL);

Linear Correlation Coefficient

>0.9999

Number of Sample Position

108 (2*54, 2mL), 96-well plates

Temperature Setting Range

4.0~40.0℃ (optional refrigeration)

Temperature Setting Value Error

±0.5℃ (optional refrigeration);

Temperature Stability

±1℃ (optional refrigeration)

Column Oven

 

Temperature Setting Range

4℃-90℃

Temperature Stability

±0.03℃/h

Temperature Setting Value Error

±0.1℃

UV Detector

 

Baseline Noise

≤8.0×10-6 Au (1mL/min, methanol, C18)

Baseline Drift

≤1.0×10-4 Au/h (1mL/min, methanol, C18)

Minimum Test Concentration

≤5×10-9 g/mL (naphthalene/methanol)

Spectral Range

188-900nm

Wavelength Error

≤ ±1nm

Wavelength Repeatability

≤ ±0.1nm

Linear Range

≥1×104 or 2.5Au

 
Performance of High Performance Liquid Chromatography Instrument
1. High-precision ultra-high-pressure infusion unit

2. Low system diffusion volume and optimized flow path

3. Needle-in-flow autosampler with ultra-low injection cycle time

4. Extremely low cross-contamination

5. Active preheat function, fast warming rate

Flow to Needle High Performance Liquid Chromatography Instrument With Binary Pump 0
 

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality Helium Leak Detector Supplier. Copyright © 2022-2025 Anhui Wanyi Science and Technology Co., Ltd. . All Rights Reserved.