Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
LC3600
150MPa Ultra High Performance Liquid Chromatography with DAD Detector
Description of High Performance Liquid Chromatography Instrument
The ultra high performance liquid chromatography instrument will complete the work of previous multiple HPLCs in less time, with higher separation, less reagent consumption, more intelligence and convenience, and greatly reduce the management cost of the instrument. It can complete the work of multiple high-performance liquid chromatographs in a shorter time with higher resolution, less reagent consumption, more intelligent and convenient and greatly reducing the management cost of the instrument.
Technical Data of High Performance Liquid Chromatography Instrument
150MPa Ultra High Performance Liquid Chromatography with DAD Detector | |
Work Power |
220V, 50Hz |
Ambient Temperature | 10-~40°C |
Relative Humidity | 20-85% |
System Indicators | |
Qualitative Repeatiblity | RSD ≤0.1% |
Quantitative Repeatability | RSD ≤0.3% |
High Pressure Constant Current Pump | |
Pump Drive Mode | Linear Motor Pump |
Gradient Mode | Binary (4-way solvent) |
Flow Setting Range | 0.0001~2mL/min |
Flow Setting Increment | 0.001mL/min |
Max Operating Pressure | 150MPa |
Flow Setting Error | ±1.1% |
Flow Stability | ≤0.09% RSD |
Gradient Stability | ≤0.02% RSD |
Column Oven | |
Temperature Setting Range | 20~90°C |
Temperature Stability | ± 0.3°C/h |
Error of Temperature Setting Value | ± 0.5°C |
Autosampler | |
Maximum Withstand Pressure | 150MPa |
Injection Volumn Range | 0.1~10μL |
Ultra-efficient DAD Detector | |
Baseline Noise | ≤10-6 AU |
Baseline Drift | ≤0.9x10-3 AU/h |
Minimum Test Concentration |
2×10-9g/mL (naphthalene/methanol) |
Wavelength Range | 190~800nm |
Wavelength Indication Error | ≤ ±1nm |
Wavelength Repeatability | ≤ ± 0.1nm |
Performance of High Performance Liquid Chromatography Instrument
1. High-precision ultra-high-pressure infusion unit
2. Low system diffusion volume and optimized flow path
3. Needle-in-flow autosampler with ultra-low injection cycle time
4. Extremely low cross-contamination
5. Active preheat function, fast warming rate
Send your inquiry directly to us