logo

Wayeal HPLC Liquid Chromatography With Quartnary Pump UV Detector

Basic Properties
Place of Origin: Anhui, China
Brand Name: Wayeal
Certification: ISO, CE
Model Number: LC3200S
Trading Properties
Minimum Order Quantity: 1
Price: Negotiation
Payment Terms: L/C, T/T
Supply Ability: 30 Pieces Per Month
Specifications
Product Name: High Performance Liquid Chromatography Instrument Power consumption: 220V,50HZ
Max operating Pressure: 45MPa Pressure pulsation: <0.1MPa
Flow accuracy: ±0.2% Flow rate stability: RSD≤0.06%
High Light:

Liquid Chromatography Instrument 42MPa

,

Wayeal Hplc Instrumentation

,

Wayeal Hplc Chromatography Instrumentation

Product Description

HPLC Liquid Chromatography Instrument with Quartnary Pump UV Detector

Introduction of Liquid Chromatography Instrument

The high performance liquid chromatography instrument with the characteristics of high operation stability, high detection sensitivity and modular designing. It is mainly used to analyze less-volatile and thermal-unstable organic compounds with high boiling point and large molecular weight in ther area of pharmaceutical, chemical, environmental, food, laboratories and other fields . It consists of reservoir, pump, sample injector, chromatographic column, detector and recorder.

Parameters of Liquid Chromatography Instrument

HPLC Liquid Chromatography Instrument with Quartnary Pump UV Detector

Physical Specifications

 

Power Requirements

220V,50HZ

Ambient Temperature

10-40℃

Ambient Humidity

20-85% relative humidity

System Specification

 

Qualitative Repeatability

RSD≤0.2%

Quantitative Repeatability

RSD≤0.4%

Pump System

 

Flow Rate Range

0.0001-10.000mL/min( increments :0.0001 mL/min)

Max Operating Pressure

45MPa

Pressure Pulsation

0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)

Flow Rate Set Error

±0.2%

Flow Rate Stability

RSD≤0.06%

Gradient Error

±1%

Column Oven

 

Temperature Setting Range

4 °C ~ 85 °C

Temperature Stability

≤0.2°C/h

Temperature Controlling Precision

±0.1 °C

Autosampler

 

Injection Volume Repeatability

< 0.5% RSD

Linearity

>0.999

Cross Contamination

<0.002%

Sample Positions

120

Syringe

250 μL( Standard, with 500μL,1000μL, 2500μL optionals)

Sample Loop

20μL( Standard, with 50μL, 100μL, 200μL optional)

Optional Sample Chamber Cooler

4 °C ~ 30 °C(4 °C lowest)

Performance of Liquid Chromatography Instrument

1. High pressure pump with electronic pulse suppression and solvent compression compensation, combined with a two-stage suspended power transmission mechanism to ensure high precision flow output and long service life

2.  Two optional gradient modes: binary high pressure and quaternary low pressure.

3. The column oven adopts air bath circulation mode to ensure constant temperature.

Product Application

Food, medicine, chemical industry, agriculture, etc.