Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
OEM FLD HPLC Detector Fluorescence for Chromatography System
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | FLD Detector HPLC Fluorescence Detector For Chromatography System | Drift | ≤2×10-4Fu/30min |
---|---|---|---|
Wavelength | 200-650nm | Noise | 1×10-5 Fu |
Packing | Wood Case Or Customized | Wavelength Accuracy | ±2 Nm |
High Light | OEM HPLC Detector,fld HPLC Detector,OEM fld fluorescence detector |
Wayeal FLD Detector HPLC Fluorescence Detector for Chromatography System
Product Introduction
Fluorescence detector
The fluorescence detector uses a DC deuterium lamp as the light source and has a dual monochromator structure, allowing flexible settings for excitation and emission wavelengths to meet your needs for different samples. It is equipped with a touch screen LCD display and a chromatography workstation with two analogue outputs and can also be used for data transfer via RS232 serial or Ethernet.
Product Parameter
Wayeal FLD Detector HPLC Fluorescence Detector for Chromatography System | |
Noise | 1×10-5 Fu |
Drift | ≤2×10-4Fu/30min |
LOD | 5.0×10-10g/mL (naphthalene/methanol) |
Wavelength range | 200-650nm |
Wavelength accuracy | ±2 nm |
Wavelength reproducibility | ±0.2 nm |
Linearity | ≥1.0×104 |
Extend functions | Wavelength bunching etc |
Product Application
Suitable for the detection of polycyclic aromatic hydrocarbons, hydrocarbons, aflatoxins, vitamins, amino acids and many other substances.