Double System Ampere Detector Ion Chromatography Instruments for Anion and Cation Testing
Introduction of Ion Chromatography Instrument
Ion Chromatography is a well established ion exchange chromatography technique for the analysis of anions and cations. In contrast to general HLPC systems, often suitable for a wide range of applications, ion chromatographs are chromatography systems specifically adapted for the analysis of anions and cations.
Features of Ion Chromatography Instrument
1. Modular design, flexible conguration, and outstanding functionality
2. Wide selection and outstanding performance chromatography pumps
3. Environmentally friendly, reagent-free ion chromatography
4. High-throughput, multifunctional autosampler design
5. Five-zone temperature control ensures uniform stability at all times
6.Five-zone temperature control mode for separation, detection and derivatization modules provides higher temperature stability.
Technical Data of Ion Chromatography Instrument
Double System Ion Chromatography Instrument with Conductivity Amperometric Detectors |
|
System Parameters |
|
Qualitative repeatability |
≤0.05% |
Quantitative repeatability |
≤0.3% |
Pump System |
|
Pump flow rate |
(0.001~12.000)mL/min |
Flow rate setting error |
<±0.1% |
Flow rate stability |
<±0.1% |
Pressure display accuracy |
0.01Mpa |
Pressure pulsation |
<0.25% |
Amperage Detector |
|
Type |
Thin layer structure, automatic range |
Driving voltage range |
-2.048V---2.048V |
Drive voltage resolution |
0.001V |
Output signal range |
50pc---200uC |
DC mode |
1pA---74uA |
Noise |
Integral mode ≤30pC |
Cell volume |
≤0.2μL |
Min detection concentration |
I-——0.001μg/mL |
Min detection concentration |
Fructose - 0.01μg/mL |
Min detection concentration |
CN-——0.0005μg/mL |
Baseline Noise | ≤0.0003μS/cm |
Baseline Drift | ≤0.001μS·cm-1/30min |
Min Detection Concentration(Cl-) | ≤0.0001ug/mL |
Min Detection Concentration (Li+) | ≤0.00005ug/mL |
Min Detection Concentration (NO3-) | ≤0.001μg/mL |
Min Detection Concentration (Na+) | ≤0.001μg/mL |
Min Detection Concentration (Ca2+) | ≤0.005μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Suppressor |
|
Constant current range |
0-500mA |
Dead volume |
50μL |
Suppressor volume |
170ueq/min |
Pressure resistance |
3Mpa |
Column Oven |
|
Temperature range |
Room +5°C~70°C |
Temperature control stability |
≤0.1℃ |
Temperature seeting error |
0.05℃ |
Autosampler(AS2800) |
|
Quantitative repeatability |
Full loop injection <0.5%RSD |
Linear |
>0.9995 |
Injection positions |
48 bits |
Industry Application
Environment, food, medicine, anions, cations, organic acids, transition metals and amines.