Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
CE
Model Number:
TQ9200
Superior Reproducibility LCMS Mass Spectrometer for Protein Anallysis
Technical Datas of TQ9200 LCMS/MS
| 
			 Working conditions  | 
			
			 
  | 
		
| 
			 Working power supply  | 
			
			 220V±22V, 50Hz±0.5Hz  | 
		
| 
			 Ambient temperature  | 
			
			 15-30°C  | 
		
| 
			 Relative humidity  | 
			
			 not more than 80%  | 
		
| 
			 UHPLC  | 
			
			 
  | 
		
| 
			 Pump drive mode  | 
			
			 linear motor pump  | 
		
| 
			 Gradient mode  | 
			
			 binary (4-waysolvent)  | 
		
| 
			 Flow rate setting range  | 
			
			 0.001-2.000mL/min  | 
		
| 
			 Flow rate setting increment  | 
			
			 0.001mL/min  | 
		
| 
			 Maximumoperating pressure  | 
			
			 150MPa  | 
		
| 
			 Degassing  | 
			
			 5-channel online degassing  | 
		
| 
			 Autosampler  | 
			
			 
  | 
		
| 
			 Maximumwithstand pressure  | 
			
			 150MPa  | 
		
| 
			 Sampling volume range  | 
			
			 0.1-20.0μL (50μL optional)  | 
		
| 
			 Linearity  | 
			
			 R≥0.9999  | 
		
| 
			 Cross-contamination  | 
			
			 <0.004 %  | 
		
| 
			 Number of samples  | 
			
			 108 (2*54,2 ml), supports 96 shallow well plate, 96 deep well plate, 384 well plate  | 
		
| 
			 Temperature setting range  | 
			
			 4.0~40.0 ℃ (optional refrigeration)  | 
		
| 
			 Temperature stability  | 
			
			 ±2 ℃  | 
		
| 
			 Feed rate  | 
			
			 12s  | 
		
| 
			 Column temperaturechamber  | 
			
			 
  | 
		
| 
			 Temperature setting range  | 
			
			 20.0-90.0 ℃  | 
		
| 
			 Temperature stability  | 
			
			 ±0.02 ℃/h  | 
		
| 
			 Temperature setting value error  | 
			
			 ± 0.1 ℃  | 
		
| 
			 Triple quadrupole mass spectrometer  | 
			
			 
  | 
		
| 
			 Mass analysis range  | 
			
			 5-1250  | 
		
| 
			 Scanning speed  | 
			
			 12000 Da/s  | 
		
| 
			 Mass resolution  | 
			
			 0.6-0.8 Da (609 mass peaks)  | 
		
| 
			 Linearity range  | 
			
			 ≥1E4  | 
		
| 
			 Mass accuracy  | 
			
			 0.1 Da  | 
		
| 
			 Massstability  | 
			
			 0.1 Da/24h  | 
		
| 
			 Limit of detection (rifampicin)  | 
			
			 0.1pg  | 
		
| 
			 Sensitivity  | 
			
			 S:N >20w:1 on a 1pg Risperdal column  | 
		
| 
			 System indicators  | 
			
			 
  | 
		
| 
			 Qualitative reproducibility  | 
			
			 RSD≤5%  | 
		
| 
			 Quantitative reproducibility  | 
			
			 RSD≤5%  | 
		
Applications of LCMS/MS:
1. Pesticide and Veterinary Drug Residues
Pesticide residues in vegetables and fruits: Organophosphates (e.g., methamidophos, chlorpyrifos).
Veterinary drug residues in meat and poultry: Sulfonamides, quinolone antibiotics.
2. Chemical and Materials Industry
Fine Chemical Product Analysis
Polymer and Additive Testing
Send your inquiry directly to us