Wayeal AA2300 Graphite Furnace AAS Atomic Absorption Spectroscopy Machine Atomic Absorption Spectrophotometer
Introduction of Atomic Absorption Spectrophotometer
Absorption spectroscopy is one of the most widely used techniques employed for determining the concentrations of absorbing species (chromophores) in solutions. It is a nondestructive technique which biologists and biochemists and now systems biologists use to quantify the cellular components and characteristic parameters of functional molecules.
Technical Datas of Atomic Absorption Spectrophotometer AA2300
Graphite Furnace Atomic Absorption Spectrophotometer AAS Wayeal AA2300 | |
Wavelength range(nm) | 185-900nm |
Wavelength indication error(nm) | ±0.15nm |
Wavelength repeatability(nm) | ≤0.05 nm |
Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, and 2.0nm |
Zero Drift | ±0.002/30min |
Instantaneous noise(Abs) | ≤0.002 Abs |
Flame Atomizer | |
Detection limit | Cu: ≤0.002μg/mL |
Repeatability | RSD≤0.25% |
Graphite Furnace Atomizer | |
Detection limit(Graphite Furnance: Cd pg) | ≤0.3pg |
Repeatability | RSD≤1.5 % |
Heating temperature | room temperature -3000°C or so |
Heating rate | 3000°C/s |
Autosampler | |
Injection bits | 108 |
Linear | >0.999 |
Injection volume | 1-200μL |
Injection volume repeatability | ≤0. 1% |
Result repeatability | ≤1.5% |
Background correction | Deuterium lamp |
Lamp position | 8 |
Features of Atomic Absorption Spectrophotometer AA2300
1. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
2. Full-reflection dual-beam optical path, high optical path stability
3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
4. 8 lamp holders preheat simultaneously to improve detection efficiency
Applications of Atomic Absorption Spectrophotometer
Atomic absorption spectrometry has many uses in different areas of chemistry such as clinical analysis of metals in biological fluids and tissues such as whole blood, plasma, urine, saliva, brain tissue, liver, hair, muscle tissue. Atomic absorption spectrometry can be used in qualitative and quantitative analysis.