• Anhui Wanyi Science and Technology Co., Ltd.
    F*Corp
    I was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
  • Anhui Wanyi Science and Technology Co., Ltd.
    A*A.S
    I enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
  • Anhui Wanyi Science and Technology Co., Ltd.
    T*Sp
    I purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
Contact Person : Larry
Phone Number : +8613586823203
Whatsapp : +8613586823203

DAD Detector HPLC Instrument In Qualitative And Quantitative Analysis

Place of Origin Anhui, China
Brand Name Wayeal
Certification ISO, CE
Model Number LC3100
Minimum Order Quantity 1
Price Negotiation
Packaging Details One piece per wooden case
Delivery Time 20 days
Payment Terms L/C, T/T
Supply Ability 30 Pieces Per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name Quaternary Pump HPLC Chromatography Detector DAD Detector
Linearity ≥1.0×104 Wavelength Accuracy 250 μL( Standard, With 500μL,1000μL, 2500μL Optionals)
Wavelength Range 190-800nm LOD 5.0×10-9g/mL (naphthalene/methanol)
High Light

High Performance Liquid Chromatography Instrument 42MPa

,

DAD Detector Liquid Chromatography Instrument

,

DAD Detector HPLC Instrument

Leave a Message
Product Description

DAD Detector Quaternary PumpHigh Performance Liquid Chromatography Instruments in Qualitative and Quantitative Analysis
 
Product Description

 

High performance liquid chromatography (HPLC) can be used to separate and identify different large biomolecules such as protein and peptides in a sample. It is based on the pumping of a sample with a solvent (mobile phase) through a column packed with sorbent material (stationary phase) at a high pressure. HPLCinstruments consist of a reservoir of mobilephase, a pump, an injector, a separation column, and adetector. Compounds are separated by injecting a sample mixtureonto the column. The different component in the mixture pass through thecolumn atdifferentiates due to differencesintheirpartition behavior between the mobile phase and thestationary phase. The mobile phase must be degassed to eliminate theformation of air bubbles.

 

Product Parameter

 

DAD Detector Quaternary PumpHigh Performance Liquid Chromatography Instruments in Qualitative and Quantitative Analysis
Physical Specification  
Power Requirements 220V,50HZ
Ambient Temperature 4-40℃
Ambient Humidity 20-85% relative humidity(non-condensing)
System  
Qualitative repeatability(Retention time) RSD≤0.3%
Quantitative repeatability(Area) RSD≤0.6%
Pump  
Flow Rate Range 0.0001-10.000mL/min( increments :0.0001 mL/min)
Max Operating Pressure 42MPa
Pressure Pulsation <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Accuracy ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Precision RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient Accuracy ±1%
Column Oven  
Temperature Setting Range 5 °C ~ 85 °C
Temperature Stability ≤0.2°C/h
Temperature Controlling Precision ±0.1 °C
Autosampler  
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity >0.999
Cross Contamination(Carry Over) <0.01%
Sample Capacity 120 Samples( 1.5ml vials)
Syringe 250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop 20μL( Standard, with 50μL, 100μL, 200μL optional)

DAD Detector

 
Noise 1.5×10-5Au
Drift ≤1×10-3Au/h
LOD 5.0×10-9g/mL (naphthalene/methanol)
Wavelength Range 190-800nm
Wavelength Reproducibility ≤±0.1 nm
Linearity ≥1.0×104

 
 
Product Performance
 
1. Two optional modes: binary high pressure and quaternary low pressure

 

2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.

 

3. A variety of detectors available, such as DAD, ELSD and FLD.

 

4. Dual-wavelength detection, two wavelengths canbe detected at the same time. 

 

 

Product Application
 
Food, medicine, chemical industry, agriculture, etc.
DAD Detector HPLC Instrument In Qualitative And Quantitative Analysis 0
 
 

DAD Detector HPLC Instrument In Qualitative And Quantitative Analysis 1

 

DAD Detector HPLC Instrument In Qualitative And Quantitative Analysis 2

 

DAD Detector HPLC Instrument In Qualitative And Quantitative Analysis 3