HPLC Chromatografia System High Performance Liquid Chromatography in Pesticide Residue Analysis
Description of High Performance Liquid Chromatography Instrument
High-performance liquid chromatography (HPLC) is an important analytical method commonly used to separate and quantify components of liquid samples. In this technique, a solution (first phase) is pumped through a column that contains a packing of small porous particles with a second phase bound to the surface. The different solubilities of the sample components in the two phases cause the components to move through the column with different average velocities, thus creating a separation of these components. The pumped solution is called the mobile phase, while the phase in the column is called the stationary phase.
Parameters of High Performance Liquid Chromatography Instrument
Binary Pump Analytical HPLC Machine High Performance Liquid Chromatography Instruments | |
Physical Specification | |
Power requirements | 220V,50HZ |
Ambient temperature | 4-40℃ |
Ambient humidity | 20-85% relative humidity(non-condensing) |
System | |
Qualitative repeatability(Retention time) | RSD≤0.3% |
Quantitative repeatability(Area) | RSD≤0.6% |
Pump | |
Flow rate range | 0.0001-10.000mL/min( increments :0.0001 mL/min) |
Max operating Pressure | 42MPa |
Pressure pulsation | <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow accuracy | ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow precision | RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol) |
Gradient accuracy | ±1% |
Seal wash | With programmable on-line seal wash module |
Column Oven | |
Temperature setting range | 5 °C ~ 85 °C |
Temperature stability | ≤0.2°C/h |
Temperature controlling precision | ±0.1 °C |
Autosampler | |
Injection Volume Precision |
<0.25%RSD( full loop) ; <0.5%RSD( partial loop) ; <1%RSD( no waste) |
Linearity | >0.999 |
Cross Contamination(Carry Over) | <0.01% |
Sample Capacity | 120 samples( 1.5ml vials) |
Syringe | 250 μL( Standard, with 500μL,1000μL, 2500μL optionals) |
Sample Loop | 20μL( Standard, with 50μL, 100μL, 200μL optional) |
DAD Detector | |
Noise | 1.5×10-5Au |
Drift | ≤1×10-3Au/h |
LOD | 5.0×10-9g/mL (naphthalene/methanol) |
Wavelength range | 190-800nm |
Wavelength accuracy | ≤±1 nm |
Wavelength reproducibility | ≤±0.1 nm |
Linearity | ≥1.0×104 |
Characteristics of High Performance Liquid Chromatography Instrument
1. Customized high-precision gradient valves, which guarantee extremely high gradient repeatability.
2. Seamlessly linked with the workstation, global set of components, high-precision metering pump, greatly enhance the accuracy of the injection.
3. Heating-cooling two way air bath temperature control, gentle control, uniform heat, high stability.
4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.