Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
HPLC Chromatography Equipment In Pesticide Residue Analysis
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | HPLC Chromatography Equipment | Sampling Volume | 0.1-20.0uL |
---|---|---|---|
Sample Volume | 120 Vials | Wavelength Range | 188 - 900 Nm |
Baseline Noise | 0.8 × 10-5 AU | Gradient Stability | < 0.5% RSD |
High Light | Pesticide Residue Analysis HPLC Chromatography Equipment,Pesticide Residue Analysis HPLC Equipment,HPLC Equipment 42MPa |
HPLC Chromatografia System High Performance Liquid Chromatography in Pesticide Residue Analysis
Product Description
HPLC is an abbreviation for High Performance Liquid Chromatography. "Chromatography" is a technique for separation, "chromatogram" is the result of chromatography, and "chromatograph" is the instrument used to conduct chromatography. Only compounds dissolved in solvents can be analyzed with HPLC. HPLC separates compounds dissolved in a liquid sample and allows qualitative and quantitative analysis of what components and how much of each component are contained in the sample.
Product Parameter
HPLC Chromatografia System High Performance Liquid Chromatography in Pesticide Residue Analysis | |
Pump System |
|
Gradient System | Quadratic Low Pressure |
Flow Rate Range | 0-11.0000mL/min |
Flow Rate Error | ±0.2% |
Flow Rate Repeatability | ≤ 0.08% RSD |
Gradient Stability | < 0.5% RSD |
Maximum Working Pressure | 42MPa |
In-line Degassing | 4 |
Column Oven | |
Temperature Range | 4 ℃ ~ 85 ℃ |
Temperature Stability | ≤±0.02 ℃ |
Autosampler | |
Injection Volume | 0.1-20.0uL |
Sample Volume | 120 Vials |
Injection Linearity | r > 0.9999 |
Cross-contamination of Injection | < 0.002% |
Injection Volume Error | ±0.2μL |
Injection Volume Repeatability | < 0.3% RSD |
Injection Time | 15 s |
Detector | |
Wavelength Range | 188 - 900 nm (optional tungsten lamp) |
Wavelength Error | ≤ ±0.5 nm |
Wavelength Repeatability | ≤ ±0.1 nm |
Baseline Noise | 0.8 × 10-5 AU |
Baseline Drift | 1.0 × 10-4 AU/h |
Linear Range | 2.5AU |
Product Performance
1. Customized high-precision gradient valves, which guarantee extremely high gradient repeatability.
2. Seamlessly linked with the workstation, global set of components, high-precision metering pump, greatly enhance the accuracy of the injection.
3. Heating-cooling two way air bath temperature control, gentle control, uniform heat, high stability.
4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.
Product Application