Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
LC3200
HPLC Chromatografia System High Performance Liquid Chromatography in Pesticide Residue Analysis
Description of High Performance Liquid Chromatography Instrument
HPLC is an abbreviation for High Performance Liquid Chromatography. "Chromatography" is a technique for separation, "chromatogram" is the result of chromatography, and "chromatograph" is the instrument used to conduct chromatography. Only compounds dissolved in solvents can be analyzed with HPLC. HPLC separates compounds dissolved in a liquid sample and allows qualitative and quantitative analysis of what components and how much of each component are contained in the sample.
Parameters of High Performance Liquid Chromatography Instrument
Manufacturer: | Wayeal |
Product Name: | Liquid Chromatography Instrument |
Working Power Supply | 220V, 50Hz |
Ambient Temperature | 10~40°C |
Relative Humidity | 20~85% |
Qualitative Repeatability | ≤0.2% |
Quantitative Repeatability | ≤0.4% |
High Pressure Constant Flow Pump | |
Flow Rate Range | 0.001~10.000mL/min |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa |
Flow Rate Set Error | ±0.2% |
Flow Rate Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Cross Contamination | <0.002% |
Injection Volume Accuracy Error | ±1% |
Sample Positions | 120 |
Injection Volume | 1~100μL |
UV Detector | |
Baseline Noise | ≤2.0*10-6Au |
Baseline Drift | ≤1*10-5Au/h |
Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
Spectral Range | 188~900nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥103 |
DA Detector | |
Baseline Noise | ≤4*10-5Au |
Baseline Drift | ≤3*10-5Au/h |
Mini Detection Concentration | ≤2*10-8g/mL |
Spectral Range | 190~800nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥ 104 |
ELS Detector | |
Baseline Noise | ≤ 0.0037mV |
Baseline Drift | ≤ 0.0026mV/30min |
Evaporation Gas Flow Range | (0 ~ 3) SLM |
Atomization Temperature Range | Room temperature ~ 90℃ |
Evaporation Temperature Range | Room temperature~110℃ |
Detection Chamber Temperature Range | Room temperature~60℃ |
Input Air Pressure | (4 ~ 7) bar |
FL Detector | |
Baseline Noise | ≤ 5×10-6 FU |
Baseline Drift | ≤ 2 × 10-5 FU/30min |
Spectral Range | (200 ~ 650) nm |
Wavelength Error | ± 0.1 nm |
Linearity Range | ≥ 104 |
RI Detector | |
Detection Range | 0.25 ~ 512 μRIU |
Linearity Range | ≥ 600 μRIU |
Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
Cell Volume | 8μL |
Characteristics of High Performance Liquid Chromatography Instrument
1. Customized high-precision gradient valves, which guarantee extremely high gradient repeatability.
2. Seamlessly linked with the workstation, global set of components, high-precision metering pump, greatly enhance the accuracy of the injection.
3. Heating-cooling two way air bath temperature control, gentle control, uniform heat, high stability.
4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.
Send your inquiry directly to us