Product Details
Product Name:
TQ9200 LCMS/MS
Maximum Operating Pressure:
150MPa
Mass Analysis Range:
5-1250
Scanning Speed:
12000 Da/s
Linearity Range:
≥1E4
Mass Accuracy:
0.1 Da
Highlight:

PCR Analyzer 5 Channels

,

Fast Testing PCR Analyzer

,

Fast Testing PCR System

Payment & Shipping Terms
Minimum Order Quantity
1 Unit
Price
Negotiation
Packaging Details
1 unit of pcr analyzer packed in wooden cases
Delivery Time
30 Days
Payment Terms
L/C, T/T, Western Union, MoneyGram
Supply Ability
30 Units/ Month
Product Description

Superior Reproducibility LCMS Mass Spectrometer for Protein Anallysis

Technical Datas of TQ9200 LCMS/MS

Working conditions

 

Working power supply

220V±22V, 50Hz±0.5Hz

Ambient temperature

15-30°C

Relative humidity

not more than 80%

UHPLC

 

Pump drive mode

linear motor pump

Gradient mode

binary (4-waysolvent)

Flow rate setting range

0.001-2.000mL/min

Flow rate setting increment

0.001mL/min

Maximumoperating pressure

150MPa

Degassing

5-channel online degassing

Autosampler

 

Maximumwithstand pressure

150MPa

Sampling volume range

0.1-20.0μL (50μL optional)

Linearity

R≥0.9999

Cross-contamination

<0.004 %

Number of samples

108 (2*54,2 ml), supports 96 shallow well plate, 96 deep well plate, 384 well plate

Temperature setting range

4.0~40.0 ℃ (optional refrigeration)

Temperature stability

±2 ℃

Feed rate

12s

Column temperaturechamber

 

Temperature setting range

20.0-90.0 ℃

Temperature stability

±0.02 ℃/h

Temperature setting value error

± 0.1 ℃

Triple quadrupole mass spectrometer

 

Mass analysis range

5-1250

Scanning speed

12000 Da/s

Mass resolution

0.6-0.8 Da (609 mass peaks)

Linearity range

≥1E4

Mass accuracy

0.1 Da

Massstability

0.1 Da/24h

Limit of detection (rifampicin)

0.1pg

Sensitivity

S:N >20w:1 on a 1pg Risperdal column

System indicators

 

Qualitative reproducibility

RSD≤5%

Quantitative reproducibility

RSD≤5%

Applications of LCMS/MS:

1. Pesticide and Veterinary Drug Residues
Pesticide residues in vegetables and fruits: Organophosphates (e.g., methamidophos, chlorpyrifos).
Veterinary drug residues in meat and poultry: Sulfonamides, quinolone antibiotics.

2. Chemical and Materials Industry
Fine Chemical Product Analysis

  • Impurities in dyes and pigments.
  • Composition analysis of surfactants (e.g., sodium dodecyl sulfate, SDS).

Polymer and Additive Testing

  • Plasticizers in plastics.
  • Antioxidants (e.g., butylated hydroxytoluene, BHT).
  • Cross-linking agent residues in rubber.