Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
LC3200
HPLC Machine High Precision Liquid Chromatography Instrument System in Phytochemical Analysis
Introduction of Liquid Chromatography Instrument
High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the mobile phase) at high pressure through a column with chromatographic packing material (stationary phase). The sample is carried by a moving carrier gas stream of helium or nitrogen. HPLC has the ability to separate, and identify compounds that are present in any sample that can be dissolved in a liquid in trace concentrations as low as parts per trillion. Because of this versatility, HPLC is used in a variety of industrial and scientific applications, such as pharmaceutical, environmental, forensics, and chemicals.
Technical Parameters of Liquid Chromatography Instrument
HPLC Machine High Precision and Efficiency Liquid Chromatography System in Phytochemical Analysis | |
Physical Specification | |
Power Requirements | 220V,50HZ |
Ambient Temperature | 4-40℃ |
Ambient Humidity | 20-85% relative humidity(non-condensing) |
System | |
Qualitative repeatability(Retention time) | RSD≤0.3% |
Quantitative repeatability(Area) | RSD≤0.6% |
Pump | |
Flow Rate Range | 0.0001-10.000mL/min( increments :0.0001 mL/min) |
Max Operating Pressure | 42MPa |
Pressure Pulsation | <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow Accuracy | ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow Precision | RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol) |
Gradient Accuracy | ±1% |
Column Oven | |
Temperature Setting Range | 5 °C ~ 85 °C |
Temperature Stability | ≤0.2°C/h |
Temperature Controlling Precision | ±0.1 °C |
Autosampler | |
Injection Volume Precision |
<0.25%RSD( full loop) ; <0.5%RSD( partial loop) ; <1%RSD( no waste) |
Linearity | >0.999 |
Cross Contamination(Carry Over) | <0.01% |
Sample Capacity | 120 Samples( 1.5ml vials) |
Syringe | 250 μL( Standard, with 500μL,1000μL, 2500μL optionals) |
Sample Loop | 20μL( Standard, with 50μL, 100μL, 200μL optional) |
FLD Detector |
|
Noise | 1×10-5 Fu |
Drift | ≤2×10-4Fu/30min |
LOD | 5.0×10-10g/mL (naphthalene/methanol) |
Wavelength Range | 200-650nm |
Wavelength Reproducibility | ±0.2 nm |
Linearity | ≥1.0×104 |
Performance of Liquid Chromatography Instrument
1. Built-in degasser to meet both high-pressure pump and feeder cleaning fluid degassing.
2. With local deploymeet and network deployment capabilities to meet the needs of users of different sizes.
3. Provide two-way "250mm column+protection column" installation position, to meet the majority of user needs.
4. High precision reflector lens, 1800 lines of shinning grating, to ensure extremely low stray light and a large linear range.
Product Application
Food, medicine, chemical industry, agriculture, etc.
Send your inquiry directly to us